Service manual for Dryer Machine
-------------------------------------------------------------------------------------------------------------------------------------------------------
-
15
-
The dryer is not suitable for installation in a mobile home.
Remove the door from all discarded appliances to avoid the danger of a child being trapped
and suffocating.
Exhausting
The dryer shall not be exhausted into a chimney, a wall, a ceiling, an attic, a crawl space, or a
concealed space of a building.
The dryer must be exhausted to the outside to reduce the risk of fire when installed in alcove or
closet.
Exhausting the dryer to the outside will prevent large amounts of lint and moisture from being
blown into the room.
NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT
If your existing ductwork is plastic, non-metal, or combustible, replace it with metal.
Use only a metal exhaust duct that is non-flammable to ensure containment of the exhaust air heat,
and lint.
Refer to the “Ducting requirements” section on page 7 for the maximum duct length and number of
bends.
All dryers must be exhausted to the outside.
Do not assemble the duct with screws or other fastening means that extend into the duct and
catch lint.
The exhaust duct should be 4 inches (102mm) in diameter.
The total length of flexible metal duct shall not exceed 7.8 feet (2.4 meters).
For usage in United States:
Use only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the
manufacturer and that comply with the outline for Clothes Dryer Transition Ducts, Subject 2158A,
shall be used.
For usage in Canada:
Use only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the
manufacturer.
For usage outside the U.S. and Canada:
Refer to the local codes.
Gas requirements
Use only natural or LP (liquid propane) gases.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF
LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, LATEST
REVISION (FOR THE UNITED STATES), OR THE NATURAL GAS AND PROPANE
INSTALLATION CODE, CSA B149.1, LATEST REVISION (FOR CANADA).
Gas dryers are equipped with a burner vent for use with natural gas. If you plan to use your dryer
with LP (liquid propane) gas, it must be converted for safe and proper performance by a qualified
service technician.
A ½" (1.27cm) gas supply line is recommended and must be reduced to connect to the 3/8" (1cm)
gas line on your dryer. The National Fuel Gas Code requires that an accessible, approved manual
gas shut-off valve be installed with 6" of your dryer.