terminals, open-end spade lugs with turned up ends, or with tinned leads.
Do not reuse a power supply cord from an old dryer. The power cord electric supply wiring
must be retained at the dryer cabinet with a suitable UL-listed strain relief.
Grounding through the neutral conductor is prohibited for (1) new branch-circuit
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes
prohibit grounding through the neutral conductor. (Use a 4-prong plug for 4 wire receptacles,
NEMA type 14-30R.)
3-Wire system connections
1. Remove the center terminal block screw.
2. Connect the neutral wire (white or center wire) of the power cord to the center. Cross the screw
through the ring of the power cord terminal and tighten the screw.
3. Connect the other wires to the outer terminal block screws. Be sure to cross the screw through the
terminal ring and tighten the screw.
4. Remove the screws for the power cord fixing base. Cross the power cord to the base, then install
back and tighten the screws. Be sure to fix the power cord tightly.
5. Insert the tab of the terminal block cover into your dryer’s rear panel slot.
6. Secure the cover with a hold-down screw.
3-wire system instructions:
A. Center terminal block screw
B. external ground connector
C. Neutral grounding wire (White)
D. Neutral wire (white or center wire)
E. 3/4" (1.9cm) UL-listed strain relief
4-Wire system connections
1. Remove the center terminal block screw.
2. Connect the ground wire (green or unwrapped) of the power cord to the external ground conductor
screw.
3. Connect the neutral wire (white or center wire) of the power cord and the appliance ground wire
(white) under the center screw of the terminal block. Cross the screw through the ring of wires’
terminal and tighten the screw.
4. Connect the other wires to the outer terminal block screws. Be sure to cross the screw through the
terminal ring and tighten the screw.
5. Remove the screws for the power cord fixing base. Cross the power cord to the base, then install
back and tighten the screws. Be sure to fix the power cord tightly.
6. Insert the tab of the terminal block cover into your dryer’s rear panel slot.
7. Secure the cover with a hold-down screw.
4-wire system instructions:
A. Center terminal block screw
B. External ground connector
A
B
C
D
E