10.4 Fan motor circuit of the freezing chamber(None)
10.5 Refrigerator fan motor circuit (None)
The fan in the freezing chamber is running when the compressor is operating. Check FAN
与
GND to see if there is
a voltage of 12V. When in normal operation, the fan is in low level and the voltage between 12V and FAN is more
than 6V. If there’s no voltage when the compressor is in operation, fan motor or electric control panel can be
replaced.
10.6 Condenser fan motor circuit(None)
Same as 10.5
10.7 Damper motor circuit(None)
10.8 Sensor resistance(R/T)
Tx(
℃
)
R(KΩ)
Tx(
℃
)
R(KΩ)
Tx(
℃
)
R(KΩ)
Tx(
℃
)
R(KΩ)
Tx(
℃
)
R(KΩ)
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486