Service Manual
, 2016-12
34
/
46
10.4
Fan motor circuit of the freezing chamber
The fan in the freezing chamber is running when the compressor is operating. Check 12V and
FAN to see if there is a voltage of 12V. When in normal operation, the fan is in low level and the
voltage between 12V and FAN is more than 11V. If there’s no voltage when the compressor is in
operation, fan motor or electric control panel can be replaced.
10.5Refrigerator fan motor circuit (None)
10.6Condensing fan motor circuit (None)
10.7Damper motor circuit (None)
10.8Resistance value of the sensor (R/T)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
Tx(
℃
)
R
(
KΩ
)
-30
33.81
-15
14.31
0
6.495
15
3.141
30
1.617
-29
31.85
-14
13.55
1
6.175
16
2.999
31
1.55
-28
30.01
-13
12.83
2
5.873
17
2.865
32
1.486
-27
28.29
-12
12.16
3
5.587
18
2.737
33
1.426
-26
26.68
-11
11.52
4
5.315
19
2.616
34
1.368
-25
25.17
-10
10.92
5
5.06
20
2.501
35
1.312
-24
23.76
-9
10.35
6
4.818
21
2.391
36
1.259
-23
22.43
-8
9.82
7
4.589
22
2.287
37
1.209
-22
21.18
-7
9.316
8
4.372
23
2.188
38
1.161
-21
20.01
-6
8.841
9
4.167
24
2.094
39
1.115
Summary of Contents for 22031020000054
Page 5: ...Service Manual 2016 12 5 46 1 Safety Warning Code 1 1Warning for operation safety ...
Page 6: ...Service Manual 2016 12 6 46 ...
Page 7: ...Service Manual 2016 12 7 46 ...
Page 8: ...Service Manual 2016 12 8 46 1 2Safety instruction for refrigerant ...
Page 18: ...Service Manual 2016 12 18 46 Down view Open Door Maximum open angle of door 135 ...
Page 36: ...Service Manual 2016 12 36 46 11 Troubleshooting Method 11 1 No refrigeration ...
Page 37: ...Service Manual 2016 12 37 46 ...
Page 38: ...Service Manual 2016 12 38 46 11 2 Compressor failure ...
Page 39: ...Service Manual 2016 12 39 46 11 3 Defrosting is not working ...