![background image](http://html1.mh-extra.com/html/midea/22031020000054/22031020000054_service-manual_1791489025.webp)
Service Manual
, 2016-12
25
/
46
1
)
Remove the air duct components in freezing
chamber.
2
)
Disconnect all connectors.
3
)
Remove the welding on inlet and outlet tubes.
4
)
Remove two screws which are used to fix the
evaporator and remove the evaporator.
Components on the evaporator
Fuse
The fuse is located on top of the evaporator
1
)
connect the fuse connector.
2
)
Cut off the band which fixes the fuse.
3
)
Separate the fuse and the evaporator.
*,Don’t break the welding of the evaporator in case that
only the fuse needs to be replaced.
Defrost sensor
The defrost sensor is located on top of the evaporator.
1
)
Disconnect the connector of defrost sensor
2
)
Cut off the band which fixes the sensor.
3
)
Separate the sensor and the evaporator.
*,Dont break the welding of the evaporator in case that
only the sensor needs to be replaced.
Defrost heater
The defrost heater is located at bottom of the evaporator.
1
)
Disconnect the connector of defrost heater.
2
)
Cut off the band which fixes the defrost heater.
3
)
Take off the defrost heater from the evaporator.
*,Dont break the welding of the evaporator in case that
only the defrost heater needs to be replaced.
Ambient temperature sensor
Summary of Contents for 22031020000054
Page 5: ...Service Manual 2016 12 5 46 1 Safety Warning Code 1 1Warning for operation safety ...
Page 6: ...Service Manual 2016 12 6 46 ...
Page 7: ...Service Manual 2016 12 7 46 ...
Page 8: ...Service Manual 2016 12 8 46 1 2Safety instruction for refrigerant ...
Page 18: ...Service Manual 2016 12 18 46 Down view Open Door Maximum open angle of door 135 ...
Page 36: ...Service Manual 2016 12 36 46 11 Troubleshooting Method 11 1 No refrigeration ...
Page 37: ...Service Manual 2016 12 37 46 ...
Page 38: ...Service Manual 2016 12 38 46 11 2 Compressor failure ...
Page 39: ...Service Manual 2016 12 39 46 11 3 Defrosting is not working ...