The temperature control indication sticker is likely
to be damaged when replacing PCB, thus it is
advised to prepare one for standby before
replacement:
Main control board
1) use cross screwdriver to remove the two screws of
main PCB cover
2) use slotted screwdriver to dismantle the PCB
cover, unplug the wiring connectors
3) use cross screwdriver to remove the screws of
main PCB, then change the main PCB. The reverse
operation is for assembly.
Summary of Contents for 22031020000054
Page 5: ...Service Manual 2016 12 5 46 1 Safety Warning Code 1 1Warning for operation safety ...
Page 6: ...Service Manual 2016 12 6 46 ...
Page 7: ...Service Manual 2016 12 7 46 ...
Page 8: ...Service Manual 2016 12 8 46 1 2Safety instruction for refrigerant ...
Page 18: ...Service Manual 2016 12 18 46 Down view Open Door Maximum open angle of door 135 ...
Page 36: ...Service Manual 2016 12 36 46 11 Troubleshooting Method 11 1 No refrigeration ...
Page 37: ...Service Manual 2016 12 37 46 ...
Page 38: ...Service Manual 2016 12 38 46 11 2 Compressor failure ...
Page 39: ...Service Manual 2016 12 39 46 11 3 Defrosting is not working ...