6.0 PERIODIC MAINTENANCE
WARNING: Disconnect the unit from the power supply before
cleaning or servicing appliance.
IMPORTANT INSTRUCTIONS
Be sure to flush your boiler water level control daily. Failure to follow this procedure can cause
the control to malfunction resulting in serious boiler damage.
The Boiler Water Level Control installed on your boiler requires periodic maintenance. As boiler
water circulates into the float chamber, sand, scale and other sediment may be deposited in the
float chamber. While the chamber has been designed with a large accumulation bowl, it is
necessary to flush the sediment from the chamber by blowing down the control so that the
accumulation of sediment does not interfere with the movement of the float in the control.
Control must be flushed at least once a day.