The product meets the requirements of the following standards: 

  • UL 1283 and UL 1449, 3rd Ed.

  • CSA C22.2 No.8-M1986, R2000

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates uses and can radiate 

radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference to radio or television 

reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures:

-- Reorient or relocate the receiving antenna.

-- Increase the separation between the equipment and receiver.

-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-- Consult the dealer or an experienced radio/TV technician for help.

Page 4

REGULATORY COMPLIANCE

Federal Communications Commission (FCC) Compliance Statement

Industry Canada (IC) Compliance Statement

 

This Class B digital apparatus co

mplies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NM

B-0

0

3

 du Canada.

Summary of Contents for PD-415R-SP

Page 1: ...utomatically powers outlets off during over under voltage conditions and automatically restores power when voltage returns to normal Thermal circuit breaker overload protection Advanced EMI RFI filter...

Page 2: ......

Page 3: ...ground pin of the AC plug Assurez vous cet appareil est connect une source d alimentation C A avec mise la terre Assurez vous cet appareil est branch sur une source d alimentation fournissant les n ce...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged...

Page 5: ...ges 8 9 Specifications Page 10 Warranty Page 11 Available in 15A or 20A models and in rackmount half rack or hard wired form factors 15A only Series Protection products provide instantaneous protectio...

Page 6: ...SP 1 2 4 7 5 6 3 ON PD 415R SP 7 4 6 5 2 3 15 AMP POWER CENTER PROTECTED WHEN LIT UNDERVOLTAGE WHEN LIT OVERVOLTAGE WHEN LIT POWER ON OFF 120V TOTAL 15A 60Hz PD 415R SP SWITCHED 20 AMP POWER CENTER P...

Page 7: ...ER TO MODELS FOR AMPERAGE RATING POWER LED Illuminates green to indicate operational status OVERVOLTAGE UNDERVOLTAGE LEDS Overvoltage LED indicates red when overvoltage condition is present Undervolta...

Page 8: ...FTER RACK EAR REMOVAL Rack Mount Screws 4 1 2 10 32 Sliding Nut 2 Rack Mount Screws 4 PD 415R SP PD 420R SP BRACKET MOUNTING Rack Mount Screws 4 Rack Mount Screws 4 Rack Mount Screws 2 Page 8 NOTE Any...

Page 9: ...ord and plug type connections to the PD HW15 SP are explicitly prohibited Ground conductor must be green with or without yellow stripe s and must be connected to earth ground at the service equipment...

Page 10: ...s only Lower Limit Cutoff Lower Limit Restore DETAILS SPECIFICATIONS 15 Amp RMS load 120 VAC 20 Amp RMS load 120 VAC 90 150V 5 watts 35 C 330V 186V for a nominal line voltage of 132V 1000 surges 6000...

Page 11: ...NTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE MAXIMUM EX...

Page 12: ......

Reviews: