The motor is a 1550 RPM shaded pole motor with auto-reset overload protection. It contains a 
centrifugal Interlock Switch which is connected in the control circuit to prevent burner operation if the 
motor fails. The motor features permanently lubricated ball bearings and requires no routine oiling 
maintenance.

Cleaning of the blower wheel is usually the only service required. Need for cleaning is required 

if the inlet screen or blower wheel shows an accumulation of dust and lint. The motor air cooling 
vents should also be cleaned at this time.

If the motor must be replaced, disconnect the motor wires from the burner terminal strip. 

Remove the blower inlet screen and blower wheel and remove the motor case bolt nuts and 
lockwashers.

When remounting the blower wheel, the distance from the wheel and the outside of the blower 

housing air inlet side plate should be 5/16″. 
 

 

  

 

    __________________________________________

The Thermal Switch is a heat sensitive single pole double throw snap switch that energizes the 
blower motor to provide cooling air if, because of a heat back up through the burner when the motor 
is off , the temperature of the blower housing reaches 160° F. The thermal switch is not wired into the 
gas valve circuit and does not turn valve off  when activated by heat back up.

The switch mechanism is a bi-metallic disc that snaps over when it is heated to the set 

temperature. The switch is mounted so that the disc bears against the side plate of the blower 
housing.

Testing the switch to prove that it is functional can be done by removing the ignitor assembly 

and blowing hot air through the opening toward the blower inlet. If hot air is not available, remove 
the switch and check for continuity. With the switch cool, there should be continuity between 
terminals 

1

 (black wire) and 

3

 (red/black wire). To simulate the “hot” condition, place the switch on 

a fi rm surface and apply fi nger pressure to the switch disc. When the disc “snaps”, there should be 
continuity between terminals 

1

 and 

2

 (red wire).

 

 

  

 

    __________________________________________

The Electronic Control is a 24 volt AC, solid state electronic device that automatically ignites and 
monitors the fl ame. It has an integral high voltage transformer and, upon fl ame startup, applies high 
voltage to the spark electrode and 24 V to the Main Automatic Gas Valve. When the fl ame is proven, 
the spark is terminated and the burner run continues.

If the fl ame is not proven within 6 seconds, or if the proof of fl ame is lost during the burner run 

and not re-established within 6 seconds, the Control will shut off  the Main Automatic Gas Valve 
and 

LOCK OUT.

 To 

reset

 the Control for restart, turn off  the Burner Switch or Timer for at least 30 

seconds and then turn back on.

If the Electronic control is changed, the replacement must be identical as to the make and

model number, or must be an authorized substitute.
 

WARNING: Explosion hazard. Do not use this device if it gets wet. It can malfunction

and cause serious injury or death. Replace any device that has been wet.

 

 

  

 

    __________________________________________

X  Blower 
Assembly

XI  Thermal 
Switch

XII  Electronic 
Control System

Summary of Contents for Incinomite J83-DS

Page 1: ...his or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately phone your gas supplier fr...

Page 2: ...000 feet by 4 for each 1000 feet of additional elevation 4 100 MBH 100 000 BTU Hr 5 Kit is available for eld installation Specifications 1 Speci cations and Installation No 1 Waste Primarily dry mater...

Page 3: ...arometric damper of the same size as the vent connector should be installed If the chimney is high enough to make it di cult for the barometric to maintain a maximum incineration chamber over re draft...

Page 4: ...800 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 PROPANE PROPANE Gas 2 500 BTU Cu Ft with 3 8 Main Gas Port 8 0 9 0 10 0 11 0 Capacities shown are for total pressure drop of 0 3 W C For higher permissible press...

Page 5: ...based on the pressure available at the inlet to the supply pipe branch line when all other gas equipment fed by the same source NATURAL gas meter or PROPANE tank regulator is ring at full rate Also ta...

Page 6: ...ION Purge outside the building Do not purge into the incineration chamber 5 Turn on the Fused Disconnect Burner Switch or Timer Let motor run long enough to accomplish four air changes Note that motor...

Page 7: ...cineration chamber pressure stays within the range of 0 to minus 0 5 W C 16 WARNING When the incinerator is located inside a building and a draft control is used check that there is no spillage of ue...

Page 8: ...to the Ground Barrier It should be audible and visible though it is rather thin and di cult to see in bright light CAUTION Circuit has 30 000 volt open circuit potential If the spark is not audible o...

Page 9: ...against the side plate of the blower housing Testing the switch to prove that it is functional can be done by removing the ignitor assembly and blowing hot air through the opening toward the blower in...

Page 10: ...Valve terminal and strip terminal 10 No voltage Electronic Control or Fuse is defective 2 Check for 24 V between strip terminals 7 and 10 No voltage blue wire from strip terminal 7 is defective 3 Chec...

Page 11: ...t 2 microamps Check sense wire for continuity Adjust ignitor gas pressure to obtain acceptable signal and note gas pressure and signal strength for future reference A Low gas pressure B Air shutter op...

Page 12: ...oria Street Chicago Illinois 60646 toll free 866 705 0514 tel 773 604 8700 fax 866 580 8700 web www midcointernational com e mail sales midcointernational com 12 Printed in USA 8470 23 ISO 9001 C O MP...

Reviews: