5
DL471 DSP
Operator Manual
Chapter 3: Rear Panel
The rear panel comprises the following:
• X and Y
AES50 audio
digital EtherCon® XLR sockets.
• Two 25-way
link
sockets for linking the DSP units together.
• X and Y
Ethernet control
digital EtherCon® XLR sockets.
• X and Y
Cobranet audio
digital EtherCon® XLR sockets (not normally connected).
• 9-way D-type socket for service access only.
• Mains IEC socket and on/off switch.
• Air outlet.
Rear panel connections
Item
Description
1
Mains IEC socket with adjacent on/off switch.
2
X and Y
AES50 audio
EtherCon® XLR sockets for passing audio and
control data to/from router.
3
Two
link
sockets for linking the backbone of the 10 DL471 DSP units.
4
X and Y
Cobranet control
EtherCon® XLR sockets. (Not normally
connected.)
5
X and Y
Ethernet control
EtherCon® XLR sockets for connection of
‘tunnelling’ Ethernet.
6
D-type connector for service access only.
Air outlet
Mains on/off switch
2
Mains IEC
connector
1
4
5
3
6