5
If the device is still in a vibrating state, MT825 will report to the server every 30
seconds/
If there is no vibration for more than 2 minutes, the device will automatically go to
sleep and report a data((event 16) to server. T is [10-86400] seconds
9.5 Network mode
9.5.1 Setup to Cat M1 network only
SMS Command format : netlock,0000,2,3,0#
Reply: netlock=Success!
Note: In this mode device will only work under Cat M1 network.
9.5.2 Setup to NB-IoT network only
SMS Command format :netlock,0000,3,3,1#
Reply: netlock=Success!
Note: Device will only work under NB-IoT network.
9.5.3 Setup to AUTO Mode
SMS Command format : netlock,0000,0,0,2#
Reply: netlock=Success!
Note: Device will auto switch to the available network include Cat M1, NB-IoT
9.6 Setup network bands
9.6.1 Lock to CAT M1 Band
SMS Command format : bandlock,0000,28,0#
Reply: bandlock=Success!
Note: Device will lock to CAT M1 B28
9.6.2
Lock to NB-IoT Band
SMS Command format : bandlock,0000,0,20#
Reply: bandlock=Success!
Note: Device will lock to NB-IoT B20.
9.7 Positioning mode
9.7.1 GPS Only
SMS Command format : locatelock,0000,gps#
Reply: locatelock=Success!
Note: In this mode device wil only enable GPS (WIFI/LBS will disable)
9.7.2 WiFi Only
SMS Command format : locatelock,0000,wifi#
Reply: locatelock=Success!
Note: In this mode device will only enable WIFI(GPS will disable)
9.7.3 AUTO
SMS Command format : locatelock,0000,auto#
Reply: locatelock=Success!