Operating condition and range:
a.
Air temperature operating range: -10
℃
~
43
℃
b.
Heating temperature setting range: 18
℃
~
40
℃
c.
Cooing temperature setting range: 12
℃
~
30
℃
The heat pump will have ideal performance in the operation range Air 15
℃
~
25
℃
Introduction of different modes:
a.
The heat pump has two modes: Boost and Silence.
b.
They have different strengths under different conditions.
3.2
Swimming pool water parameters
The heat pump is designed for heating the swimming pool water. Although the water heat exchanger is made
from the most durable titanium, in order to ensure long term reliability of the heat pump the pool water must
be in accordance with the related sanitary requirements.
The limit values for the heat pump operation are the following:
-
pH value ranging from 6.8 to 7.9,
-
total chlorine amount not exceeding 3 mg/l,
-
salt content 6% wt/wt.
Should you have different values of pH, chlorine or salt please try to apply appropriate agents or contact your
swimming pool builder to resolve the situation. Above mentioned values are recommended for pools in
general.
It is also advised to keep the water hardness on the lower limit of the optimal range, i.e. closely above 8 °N.
Mode
Modes
Strength
Boost mode
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fast heating
Silence mode
Heating capacity: 20% to 80% capacity
Sound level: 3dB (A) lower than Boost mode