I n s t a l l a t i o n a n d u s e r m a n u a l
H P 1 0 0 0 / 1 4 0 0 G r e e n
V e r s i o n : 0 1 / 2 0 1 9
P a g e
1 0
/ 3 2
H
E
A
T
P
U
M
P
M
I
C
R
O
W
E
L
L
H
P
3.
TECHNICAL SPECIFICATION
3.1
Technical data
Model
HP1000 GREEN INVERTER
PRO
HP1400 GREEN INVERTER
PRO
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
10.8
15
COP Range
14~6.4
15~6.6
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
7.7
10.5
COP Range
7.5~4.5
7.7~4.6
PERFORMANCE CONDITION: Air 35°C/ Water 28°C/ Humid. 80%
Cooling capacity (kW)
4.5
6.7
TECHNICAL SPECIFICATIONS
Advised pool volume (m
3
) *
30~40
40~60
Operating air temperature (
℃
)
-10
℃
~43
℃
Rated input power (kW)
0.20~1.71
0.27~2.28
Rated input current (A)
0.87~7.4
1.17~9.91
Maximum input current (A)
10
13.5
Power cord
(
mm²
)
3X2.5
3X2.5
Sound level at 10m dB(A)
18.1~29.4
20.8~24.5
Advised water flow (m³/h)
3~5
5~7
Water connection (mm)
50
Compressor
Full Stepless DC inverter compressor
Fan
DC Inverter
Expansion
EEV
Casing
ABS UV resistant on a metal chassis
Heat exchanger
Titanium Grade 2 ASTM B338M, twisted tube in plastic
body
Winter accessories
Winter module (compressor heater) and condensate tray
heater
WIFI
Standard worldwide, IEEE802.11 b/g/n;
2,412 - 2,484 GHz
* The manufacturer reserves the right to change the parameters without notice.
** In the case Winter module, condensate tray antifreeze or heat exchanger frost protection is installed.
The refrigerant circuit is filled with R32.
Refrigerant R32 also called HFC-32 or difluoromethane. R32 is a molecule used as refrigerant that has zero
ozone depletion potential (ODP).
R32 with the global warming potential (GWP) index 675 times that of carbon dioxide, based on a 100-year time
frame, and it is classified as A2L - slightly flammable by ASHRAE.