WALL-MOUNTED SWIMMING POOL DEHUMIDIFIER - OWNER´S & INSTALLATION MANUAL
The LPHW heater elements are supplied only to order. Connection of the hot water heater element onto the LPHW plumbing is
carried out similarly to the installation of radiators. On the feeder pipe, it is connected by a control valve and on the return pipe by a
closing screw joint. The LPHW is not supplied with a control valve and a screw joint; these are supplied by the supplier
of the heating.
6.7.
LPHW heater element - to order
After installing the LPHW plumbing and leading the LPHW into the element under pressure, it is necessary to bleed the heater
element. The bleeding valve is located on the feeder pipe of the LPHW heater element. To secure that the LPHW heater element
works always at full heat output, blowing onto the unit by a fan must be provided even when no dehumidification is being
performed. Therefore, when using the LPHW heater element, the switch of fan operation must be switched into the position of
continuous operation.
Attachment of the heater element to the distribution of the heating water
50 100
44
11
7
50
15
LOCATION OF CONNECTION- FROM BACK SIDE
THREAD G ½ '’ MALE
POWER SUPPLY
CYSY WIRE 3C x 1.5 (3C x 2.5) mm
(FROM THE REAR)
2
CONDENSATE DRAINAGE (FROM THE REAR)
PIPING WITH MINIMUM INTERNAL DIAMETER OF 18 mm