88
MDS entraNET 900 System Guide (Preliminary)
MDS 05-4055A01, Rev. A
resolving common system difficulties using the LEDs, and
other simple techniques.
4.1.2 Troubleshooting Using the Embedded
Management System
If you have looked over and tried the things mentioned in
and
still have not resolved the problem, there are some additional tools and
techniques that can be used. The embedded Management System is a
good source of information that may be used remotely to provide pre-
liminary diagnostic information, or may even provide a path to cor-
recting the problem.
Table 4-1. Troubleshooting Using LEDs—Symptom-Based
Symptom
Problem/Recommended System Checks
PWR LED does not
turn on.
a. Voltage too low—Check for the proper supply voltage at
the power connector. (10.5–30 Vdc)
b. Indefinite Problem—Cycle the power and wait
(
≈
30 seconds) for the unit to reboot. Then, recheck for
normal operation.
LINK LED does not
turn on.
a. Network Name of Remote not identical to desired Access
Point—Verify that the system has a unique Network Name.
b. Not yet associated with an Access Point with the same
Network Name.
Check the “Status” of the unit’s process of associating with
the Access Point. Use the entraNET Management System.
c. Poor Antenna System—Check the antenna, feedline and
connectors. Reflected power should be less than 10% of
the forward power reading (SWR 2:1 or lower).
PWR LED is
blinking.
a. Blinking indicates an alarm condition exists.
b. View Current Alarms and Event Log and correct the
problem if possible.
(
See “Using Logged Operation Events” on Page 92
c. Blinking will continue until the source of the alarm is
corrected, for example, a valid IP address is entered, etc.
LAN LED does not
turn on.
a. Verify the Ethernet cable is connect at both ends.
b. Verify that the appropriate type of Ethernet cable is used:
straight-through, or crossover.
Table 4-2. Basic Troubleshooting with the entraNET MS
Symptom
Problem/Recommended System Checks
Remote does not
associate; stays in
HOPSYNC
a. Verify the AP has sufficiently large number in the “Max
Remotes” parameter of the Network Configuration Menu.
b. Verify the correct MAC address is listed in the “Approved
Remotes List” or “Approved Access Points List” of the
Security Configuration menu.
Serial data is slow
with UDP multicast
traffic
a. Change Beacon Period to FAST.
(Radio Configuration Menu)
Summary of Contents for MDS entraNET 900
Page 2: ......
Page 8: ...vi MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 10: ...2 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 82: ...74 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 84: ...76 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 92: ...84 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 94: ...86 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 108: ...100 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 110: ...102 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 122: ...114 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 139: ...MDS 05 4055A01 Rev A MDS entraNET 900 System Guide Preliminary 131 ...
Page 140: ...132 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 148: ...140 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...