MDS 05-4055A01, Rev. A
MDS entraNET 900 System Guide (Preliminary)
77
3.1
OVERVIEW
It is convenient to set up a tabletop network that can be used to verify
the basic operation of the transceivers and give you a chance to experi-
ment with network designs, configurations or network equipment in a
convenient location. This test can be performed with any number of
radios.
NOTE:
It is important to use a “Network Name” that is different from
any currently in use in your area during the testing period. This
will eliminate unnecessary disruption of traffic on the existing
network while you become familiar with the transceiver or
evaluate variations of unit operating parameters.
To simulate data traffic over the radio network, connect a PC or LAN to
the Ethernet port of the Access Point and PING each transceiver several
times.
3.2
STEP 1—INSTALL THE ANTENNA
CABLING
is a drawing of the tabletop arrangement. Connect the
antenna ports of each transceiver as shown. This will provide stable
radio communications between each unit while preventing interference
to nearby electronic equipment from a large number of co-located units.
Invisible place holder
Figure 3-1. Typical setup for tabletop-testing of radios
NOTE:
It is very important to use attenuation between all units in the
test setup. The amount of attenuation required will depend on
the number of units being tested and the desired signal strength
(RSSI) at each transceiver during the test. In no case should a
signal greater than –50 dBm be applied to any transceiver in
the test setup. An RF power output level of +20 dBm is recom-
mended. (
See “Radio Configuration Menu” on Page 29
.)
POWER ATTENUATORS
• Fixed or adjustable
• 1W Minimum Rating
POWER DIVIDER
NON-RADIATING ATTENUATORS
• Install on unused divider ports (if any)
• 1W Minimum Rating
COMPUTER
PWR
SYN
C
TXD
RXD
RX
D
TX
D
SY
NC
PW
R
PWR
SYN
C
TXD
RXD
Remote
Remote
Access Point
Remote
Summary of Contents for MDS entraNET 900
Page 2: ......
Page 8: ...vi MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 10: ...2 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 82: ...74 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 84: ...76 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 92: ...84 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 94: ...86 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 108: ...100 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 110: ...102 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 122: ...114 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 139: ...MDS 05 4055A01 Rev A MDS entraNET 900 System Guide Preliminary 131 ...
Page 140: ...132 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...
Page 148: ...140 MDS entraNET 900 System Guide Preliminary MDS 05 4055A01 Rev A ...