III.

OPERATING MODE

The   unit   registers   the   input   pulses   and   increases  the   accumulated   value.   Upon

reaching   the  set   point,  output   K1   changes   its   state   or   generates   a   pulse   of   a   certain
duration (see PROGRAMMING mode). The input pulses are blocked until a 

Reset

 input

signal resets the counter readings and changes the output status. A new counting starts
after Reset is dropped.

The output status is indicated by LED K1.

The action of the individual buttons is as follows:

 By pressing and holding this button for more than 2 seconds, a mode of setting 

the limit of accumulated pulses is entered. The display shows a limit value that can be 
edited using the 

UP and DOWN

 buttons. To save the edited value, press the MODE 

button again or do not press the button for more than 5 seconds.

 , 

 When one of the two buttons is pressed, the display shows the number 

of cycles performed by the counter (it is considered a completed cycle each time the 
accumulated value is reset).

While pressing buttons 

 and 

 simultaneously the cycle counter is reset

 Pressing and holding this button for more than 5 seconds enters the 

"PROGRAMMING" mode, which is indicated by the red LED.