background image

 

Thanks  for  your  using  products  from  MICROSENSOR.  MPM4841 

Pressure Transmitter is one of precise instruments. We suggest you to 

read this manual carefully before use. 

1 Introduction 

MPM4841 pressure transmitter is new pressure transmitter developed by 

our  company.  A  piezo-resistive  pressure  sensor  with  316L  isolated 

diaphragm  is  mounted  with  the  high-performance  signal  processing 

circuit in the stainless steel housing. The Sensor is automatically tested 

by computer and compensated zero and temperature in wide range by 

laser trimming system. The digital circuit processes the sensor signal into 

standard output signal. 

The product is suitable widely for pressure measurement of petroleum, 

chemi-industry,  metallurgy,  electric  power,  light  industry,  cottoncracy, 

building material, hydrogeology and other country economic fields. 

2 Specifications 

Pressure Range:Type A

0bar~0.35bar…200bar 

Type B

0bar~250bar…600bar 

Overpressure: ≤2 times FS 

Pressure Type: Gauge, Absolute or Sealed gauge   

Accuracy: 

≤±

0.25%FS     

≤±

0.5%FS     

≤±

1%FS 

Note: The precision of products is related to the range of measurement, 

Summary of Contents for MPM4841

Page 1: ...MPM4841 Operation Manual...

Page 2: ...tion manual due to renovation of production technology and craftwork If some information is changed no more notice will be edited Please pay attention to the latest version Our company also reserves t...

Page 3: ...omatically tested by computer and compensated zero and temperature in wide range by laser trimming system The digital circuit processes the sensor signal into standard output signal The product is sui...

Page 4: ...Signal Output 4mA 20mADC 2 wire 0 1V 5 10VDC 3 wire 0 5V 4 5VDC 3 wire Operation Temperature 30 80 4 pin Plug M12x1 Plug 20 70 cable material PE PVC 20 80 cable material PUR Storage Temperature 40 12...

Page 5: ...3 B1 SW19 50 78 27 SW27 G1 8 30 SW19 27 SW27 30 G1 8 50 105 B2 G1 8 27 17 5 60 5 SW27 SW27 27 G1 8 17 5 90 5...

Page 6: ...be mounted vertically up to the horizontal direction If the condition is unavailable the allowed max mount slope angle from transmitter to the horizontal direction is 30 degree It is not recommended...

Page 7: ...hing hard and do not press the diaphragm with finger or something sharp to protect the diaphragm The recommended method is to see Fig 2 Pressure Transmitter Valve Pipe Fig 2 4 Electric Connection 4 1...

Page 8: ...be blocked or water infl ow and it must be connected to the atmosphere to ensure the pr otection of the product and the accuracy of the output measureme nt The electric definitions of M12x1 Plug are a...

Page 9: ...ed with clear numbers Please choose 4 9mm shield cable and connect the cable reliably to prevent short circuit d Pull the cable slightly and push the plug core into housing a rattling sound could be l...

Page 10: ...cial Plug 1 Production Manual 1 Production Qualification Certificate 1 5 3 Storage The transmitter should be stored in dry ventilate room ambient temperature 40 120 20 85 Cable type and the relative h...

Page 11: ...ot connect it at will to protect the transmitter c The transmitter and the external circuit connect through the speci al plug seat When the installation of electrical connection is comp leted be sure...

Page 12: ......

Reviews: