7 Installation
The electromagnetic flowmeter must work under the condition of full pipe, and the flowmeter cannot work
normally when the pipe is not full or empty.
During installation, the positive direction of liquid flow should be consistent with the direction of the flow
arrow on the sensor, and there must be enough space for installation and maintenance near the
flowmeter. as shown in Figure 1.
When installing the plug-in electromagnetic flowmeter, in order to eliminate the influence of the gas at the
top of the pipeline, it is generally recommended to install the plug-in electromagnetic flowmeter on a
horizontal line, or at a position of 30
°~
45
°
with the horizontal line.
Figure 1
The correct installation method of the plug-in electromagnetic flowmeter must ensure that the pipeline is
filled with liquid, so the electromagnetic flowmeter needs to be installed at the low point of the pipeline
and cannot be installed at the high point of the pipeline, as shown in Figure 2.