Fabric Interface Controller
UG0331 User Guide Revision 15.0
758
The following table lists the number of FICs available for use in each device.
24.1
Functional Description
This following sections provide a detailed description of the FIC subsystem.
Figure 327 •
Fabric Interface Controller Block Diagram
The preceding figure shows a block diagram for the FIC. The FIC is a hard block; enabling or disabling it
will not consume any user logic. You can configure FIC_0 and FIC_1 independently from the Libero SoC
MSS configurator. The following configuration options are available.
•
The MSS to the FPGA fabric interface
•
Advanced AHB-Lite options
•
The FPGA fabric Address Regions (MSS Master View)
Table 777 •
Number of FICs Available for Use in Each Device
Device
FIC Blocks
M2S005
1
1
1.
Only FIC_0 is available.
M2S010
M2S025
M2S050
2
M2S060
1*
M2S090
M2S150
2
AHB Bus Matrix
AHB-Lite Master
Interface
AHB-Lite Master
Interface
AHB-Lite / APB
Slave Interface
AHB-Lite / APB
Master Interface
AHB-Lite / APB
Master Interface
AHB-Lite / APB
Slave Interface
AHB-Lite
MSS
AHB-Lite
AHB-Lite Slave
Interface
AHB-Lite Slave
Interface
Fabric Interface Controller
Fabric