Testing the Board
UG0048 User Guide Revision 5.1
21
If an error message of incorrect VJTAG is reported, then remove the jumper placed at J5 and place
it instead at J12 across pins 11 and 12. It may safely be left there. Repeat the Analyze Chain com-
mand.
If a message appears indicating that an A3PE1500 part (depending on the device fitted to the board)
has been detected, then the board has passed this test. Leave the silicon in place in the socket and
move to the next step.
If a message of 11 or some other numeric indication appears, then record the message in a test log
and fail the board. Remove the silicon from the socket and place it in the safe silicon holding area.
21. This concludes the testing of the board. Switch SW11 to the OFF position and remove the power
connector from J18.