For SNMPv3, make sure username, authentication and privacy password and encryption methods
match your SNMP manager configuration.
2. Traps:
To enable traps set remote manager IP address in the
Remote IPv4/IPv6 SNMP Trap Managers
window.
To enable PoE traps (PoE port status changed, unit consumes over xy% of total unit power, or unit now
consumes less than xy% of total unit power), please enable PoE Notifications (see image below).
Figure 5-2: Enable SNMPv2, SNMPv3 and PoE traps
5.2 SNMP MIBs
Several MIBs are supported by SNMP manager.
RFC1213
: MIB-II which provides general IPv4 network statistics, and information on the device being
managed.
RFC3621
: Power Over Ethernet (PoE) MIB which provides various management capabilities (see
Private MIB
: Enhance PoE functionality beyond RFC3621 PoE MIB.
5.3 RFC3621 PoE MIB
NOTE:
For a detailed PoE MIB description, please
refer to Microsemi’s Technical Note – 132 (can be
found on the CD), which describes in detail PoE MIB functionality
.