RFC3621 PoE MIB is located under 1.3.6.1.2.1.105 SNMP MIB tree. The MIB is divided into three sections (see
Figure 5-3). The first section deals with PoE ports and provides functionality such as enable/disable, read port
status, class, etc. Each OiD is accessed as a two-dimensional array table.
The second section deals with the power source that is responsible for providing power to a group of PoE ports.
It enables reading total power consumption, power supply status, etc.
The third section enable/disables PoE traps to be sent to remote SNMP managers.
Figure 5-3: MIB Tree Structure
5.4 Private MIB
The following SNMP OiD's are supported by the SNMP private MIB
OiD Name
Type
(R/W)
Description
poePortConsumptionPower
R
PoE port power consumption [Watt]
poePortMaxPower
R
PoE port maximum available power [Watt]
poePortType
R
PoE port type
– Two Pair, 30 [Watt]
mainVoltage
R
Unit Power Supply voltage [Volt]