Indicator status on the Control panel
Off
On
Flashing
Red
Yellow
Green
Information
Only mains indicator
is lit. Charger is waiting for a battery to be connected.
The charging process has been manually stopped. Press
STOP
to resume charging.
A battery is connected to the charger and a charging is in progress.
Equalize charging in process.
A battery is connected to the charger and the charging process is completed.
A battery is connected to the charger but charging is restricted. The restriction can be
due to settings in the Time restriction, Remote in function or during a BMU
initialization.
An alarm is active, no specific.
Alarm, low battery voltage.
Alarm, high battery voltage.
Alarm, time limit exceeded.
Alarm, Ah limit exceeded.
Alarm, invalid charging parameters.
Alarm, high charger temperature.
Alarm, low charger temperature or sensor fault.
Alarm, regulation fault.
Alarm, battery error.