10 Performance Data MLR003RiEU61-07-1.1
Parameter
Range
Ambient operating temperature
0 to 40°C, max 70% rH
Flow pipe temperature
75°C max
Transportation & storage temperature range
-20 to +65°C, max 70% rH
Dimensions (LWH)
83 x 60 x 64 mm (63 x 60 x 64 without valve
connector)
Weight
280 g (not including packing)
Operation at high altitude
Max 2000 m / 6500 ft above sea level
Max pin stroke (calibration range)
> 5.5 mm
Operating pin stroke (0-100%)
2.56 mm typical
Pin Stroke Resolution
Steps of 1%
Adjustment speed
0.727 mm/s typical
Stall force
100N
Noise level
< 35 dB(A) @ 70 N load
Radio Communication Interval (default)
10 minutes
Radio Communication Interval during Installation Cycle
10 seconds for 5 minutes
Radio Communication attempt Interval (after join fail or
6 consecutive communication fails)
3 * 10 seconds
Then 2 minutes
Then 60 minutes