![Micropelt MLR003 User Manual And Device Specification Download Page 17](http://html1.mh-extra.com/html/micropelt/mlr003/mlr003_user-manual-and-device-specification_1788145017.webp)
Copyright Micropelt
Communication Profile MLR003RiEU61-07-1.1
–
17
8.1 FPORT 0x01 UPLINK: MLR003RiEU61-07-1.1 to Controller / Network Server
BYTE
BIT RANGE
SIZE
OFFSE
T
ABB
REV.
DETAILS
1
DB0.7…0.0
8
0
CVP
Current Valve Position %
0x00 … 0x64 / 0 … 100%
Res = 1%
2
DB1.7…1.0
8
8
FSR
V
Flow Sensor RAW Value °C
0x00 … 0xFF / 0 … 125.0°C
Res = 0.5°C
3
DB2.7…2.0
8
16
FTM
P
Flow TEMPERATURE Value °C
0x00 … 0xFF / 0 … 125.0°C
Res = 0.5°C
4
DB3.7…3.0
8
24
ASR
V
Ambient Sensor RAW Value °C
0x00 … 0xFF / 0 … 63.75°C
Res = 0.25°C
5
DB4.7…4.0
8
32
ATM
P
Ambient TEMPERATURE Value °C
0x00 … 0xFF / 0 … 63.75°C
Res = 0.25°C
6
DB5.7
1
40
RESERVED
DB5.6
1
41
ES
Energy Storage is low
1 = Battery is low
DB5.5
1
42
HA
Harvesting
1 = Harvesting is active
DB5.4
1
43
ASF
Ambient Sensor Failure
1 = Sensor Failure