c.

 

Using a clean, dry towel, thoroughly wipe the installation area, making sure 
the surface is clean and dry.

d.

Use the provided alcohol wipe and thoroughly clean the installation area.

e.

Again, using a clean, dry towel, thoroughly wipe the installation area, making 
sure the surface is clean and dry.

Prepare & Mix 2-Part adhesive 

Before mounting the TREQr-5 device to the vehicle windshield, the 2-part 

liquid adhesive must first be prepared. Follow these instructions precisely.

 

Prepare & Mix 2-Part adhesive:

 

a.

Locate the 2-Part liquid adhesive included in the Installation Kit.

b.

Mix the adhesive as follows:

If the two halves of the packet are separated by a mechanical clip, 
remove the clip to mix the adhesive. If the packet is separated by a 
bonded strip, squeeze on one side until liquid bursts through to the 
other side.

Thoroughly mix the two adhesive parts by squeezing all of the liquid 
from one end to the other, while kneading the packet. Do this several 
times to ensure a thorough mixing, paying particular attention to the 
corners of the packet.

Important

 

note

:

   

The total amount of time between mixing the adhesive and mounting 
the TREQr-5 device on the vehicle windshield should be approximately 

five (5) minutes or less. 

Install TREQr-5 Device 

After completing previous steps, the TREQr-5 device can be installed on the 

vehicle windshield. Note: Windshield and device must be at least room 
temperature before attempting to install the unit. Heat the windshield if 
necessary. 

 

Mount TREQr-5 Unit to Vehicle windshield:

 

a.

Remove the adhesive backing (red dots) protecting the adhering surfaces of
the adhesive pads on the TREQr-5 unit.

b.

Cut the corner of the adhesive packet, creating a small opening to squeeze the 
adhesive from, then waste a small amount of the adhesive on a towel before 
applying to the unit.

c.

 

Apply approximately one (1) drop of the mixed adhesive to the center of the 
upper-left, and lower-right adhesive pads.

Important:

 Only apply adhesive to the upper-left and lower right adhesive 

pads on the TREQr-5 device. 

 

Apply 1 drop of the mixed adhesive to the center of 2 diagonal pads 

on the TREQr-5 unit

 

d.

Install TREQr-5 in predefined area. Apply sufficient pressure to adequately 
secure the device in place. Hold firmly in place for approximately 60 seconds.
Be careful to not press the green button while mounting the unit.

Important:

 The TREQr-5 unit must be installed so that the device cable points 

downward from the device for correct orientation. 

 

e.

Locate the vehicle diagnostic port (OBD-II or 6/9-Pin), typically located
underneath dash on driver side. If unable to locate, refer to the vehicle’s
owner manual.

f.

Route the TREQr-5 cable to the vehicle diagnostic port using the most efficient 
route possible, keeping in mind Micronet’s standard for quality, professional 
workmanship.

g.

Securely plug TREQr-5 cable into the vehicle diagnostic port.

h.

Secure excess cable as needed, using provided cable ties, in a location that will 
not interfere with normal operation of the vehicle.