Setup and Calibration
21
www.tacktick.com
Leg 1-2 Angle
The angle at which the auto leg page switches from the Leg1
page to the Leg 2 page. The default is
60 degrees
.
Leg 2
Sets the autoleg page to be displayed while the apparent wind
angle is between the leg 1-2 changeover angle and the leg 2-3
changeover angle. The default is
True Wind Direction
.
Pages can be selected from any currently unhidden page.
Leg 2-3 Angle
The angle at which the auto leg page switches from the Leg2
page to the Leg 3 page. The default is
120 degrees
Leg 3
Sets the autoleg page to be displayed while the apparent wind
angle is between the leg 2-3 changeover angle and 180 degrees.
The default is
VMG to Windward
.
Pages can be selected from any currently unhidden page.
Autoleg Chapter - Lower Pane
Configures the Auto Leg pages for the lower pane. The same functions
are available as in the Autoleg Chapter - Upper Pane.
Memories Chapter
Note:
all memories are cleared when the system is powered on.
Trip
Clears the trip memory, resets to 0.0.
Minimum Depth
Resets the Minimum Depth memory; resets to the current depth.