Micromark MM23207 Installation & Operating Instructions Manual Download Page 11

TO ARM THE SYSTEM

TO DISARM THE SYSTEM

CHIME ZONE

PANIC ALARM

Full Guard means that you have placed
all of the zones covered by sensors into
the armed mode. Should you or an
intruder enter a zone covered by these
sensors the sirens will sound. 
B

Be

effo

orre

e  yyo

ou

u  cca

an

n  a

arrm

m  tth

he

e  ssyysstte

em

m,,  e

en

nssu

urre

e

tth

ha

att  d

do

oo

orrss  o

orr  w

wiin

nd

do

ow

wss  cco

ovve

erre

ed

d  b

byy  d

do

oo

orr

cco

on

ntta

accttss  a

arre

e  ccllo

osse

ed

d,,  a

an

nd

d  tth

ha

att  n

no

o  zzo

on

ne

e

LLEED

Dss  o

on

n  tth

he

e  cco

on

nttrro

oll  p

pa

an

ne

ell  a

arre

e  iillllu

um

miin

na

atte

ed

d..

Enter your password
(e.g. P

P  11112

22

2  EE) to go into

programming mode.

EEn

ntte

err  yyo

ou

urr  P

Pa

assssw

wo

orrd

d..

Exit the premises. 
A continuous tone will
be heard from the
control panel followed
by 4 bleeps.

1

??

??

??

??

N

NO

OTT  A

AC

CTTIIV

VA

ATTEED

D

K

Ke

eyy  iin

n  p

pa

assssw

wo

orrd

d. Bleeps will stop with

Power LED on.
A

AC

CTTIIV

VA

ATTEED

D

K

Ke

eyy  iin

n  p

pa

assssw

wo

orrd

d. Siren will stop (internal

and external). Zone LED will flash indicating
the triggered zone.
EEn

ntte

err  p

pa

assssw

wo

orrd

d again to reset.

To operate the Panic alarm
p

prre

essss  P

P  a

an

nd

d  EE together until

alarm sounds (status LED on).

EEn

ntte

err  p

pa

assssw

wo

orrd

d to stop alarm. 

EEn

ntte

err  p

pa

assssw

wo

orrd

d  again to reset

system.

1

??

??

??

??

2

??

??

??

??

Should you want to cancel arming, enter your
password again while the system is sounding the
exit time. 
Note that each zone activated during the armed
period will be indicated by a corresponding LED on
the control panel when disarmed.

You can arm a zone to activate the internal siren only. This is useful if the system is not fully armed, but you need to know
of unauthorised entry in a particular zone. All zones can run concurrently as chime zones.

IIff  tth

he

e  ssyysstte

em

m  w

wiillll  n

no

ott  a

arrm

m

a) Tamper switch on the control panel is not fully
depressed.
b) Bell box is not connected correctly
c) A zone has been activated.
Check above and reset system pressing 11112

22

2  or your

password. The LED should extinguish.

1

11

1

1

EE

??

??

??

??

EE

P

P

P

P

??

??

??

??

2

To cancel a chime zone
enter the factory pre-set
code or your password.

Then press P

P  5

5  EE  0

0  EE.

To exit programming
press P

P  0

0  EE.

3

To exit programming
press P

P  0

0  EE.

2

TTO

O  C

CA

AN

NC

CEELL  A

A  C

CH

HIIM

MEE  Z

ZO

ON

NEE

TTO

O  SSEETT  A

A  C

CH

HIIM

MEE  Z

ZO

ON

NEE

P

P  5

5  EE  11  EE for zone 1

P

P  5

5  EE  2

2  EE for zone 2

P

P  5

5  EE  3

3  EE for zone 3

P

P  5

5  EE  4

4  EE for zone 4

You have 5 seconds to
enter the relevant code.

www.ukpanels.com

Summary of Contents for MM23207

Page 1: ...all an Alarm System Since the requirements of each Authority differ we suggest that you contact the Environmental Officer of your local Borough for full information about your local area s by laws Ple...

Page 2: ...above a heat source such as radiator or in conservatories or draughty areas When this system is armed keep pets out of areas protected by PIR sensors Position control panel near a power socket Now st...

Page 3: ...N EXISTING DOOR CONTACT TYPICAL WIRING DIAGRAM SHOWING PIR AND DOOR CONTACTS WITHIN ZONE 1 THE ENTRY EXIT ZONE BLACK WIRES TWISTED AND TAPED TOGETHER TRIM RED WIRES BACK TO INSULATION AND COVER WITH T...

Page 4: ...ing and pipework When planning the wiring avoid awkward cable runs to the control panel siren box PIRs and door contacts 1 Install the control panel out of reach of young children Mark for two vertica...

Page 5: ...y plugs 9 Bring the cable to the positon of the siren box and cut the cable allowing enough surplus for wiring into the siren terminal block Strip the wires and connect them to the teminal block as sh...

Page 6: ...ed cable through and connect the wires to the terminal block observing the colours Replace the cover and screw Use a sticky pad and secure the PIR to the mounting surface Run the cable back to the con...

Page 7: ...m cable see accessories and cut short the blue wire Anti tamper spring Tape down the anti tamper spring Figure 5 before connecting the back up battery otherwise as soon as the back up battery is conne...

Page 8: ...it t p pr ro og gr ra am mm mi in ng g P Pr re es ss s P P 6 6 E E All zones LEDs will flash with the control panel siren and the outside siren sounding for 15 seconds P Pr re es ss s P P 0 0 E E t to...

Page 9: ...to exit after arming the system with the password before the sirens sound The exit time is set by the factory to 15 seconds but this can be changed to a choice of 7 other exit times to suit you If for...

Page 10: ...s s P P 1 11 12 22 2 E E t to o e en nt te er r p pr ro og gr ra am mm mi in ng g Status LED flashes 3 1 E E SETTING UP CHECK LIST Have you done the walk test Have you done the bell test Have you set...

Page 11: ...re es ss s P P a an nd d E E together until alarm sounds status LED on E En nt te er r p pa as ss sw wo or rd d to stop alarm E En nt te er r p pa as ss sw wo or rd d again to reset system 1 2 Should...

Page 12: ...L La an ne e L Lo on nd do on n N N1 17 7 7 7R RQ Q Micromark continuously tries to improve its products for the benefit of its customers For this reason we reserve the right to make changes to any pr...

Reviews: