Microlife FR1DQ1-B User Manual Download Page 11

This thermometer can recall the last 30 readings with a record of both time and date. 

 

Recall mode

16

Press the MEMO button

5  to enter recall mode when the power is off or in measuring mode. 

The memory icon «

M

» will display. 

 

Reading the last reading

17

:

 

Press and release the MEMO button

5  

to recall the last reading. Number «1» and «

M

» are 

displayed. 

 

Pressing and releasing the MEMO button

5  

after the last 30 readings have been recalled will resume the above sequence from 

reading. 

After memory recall 

1.

 

Press “Start/ IO” button to go back to ready for measuring   

2.

 

Press “Start/ IO ” button for 3 seconds to switch off.     

3.

 

If no button be press for 30 seconds, the device will auto off. 

 

10. Bluetooth

R

 Function 

This device can be used in conjunction with a smart phone running the   

«Microlife Connected » App. The measurement results will be automatically transferred via Bluetooth®.   

App Quick start guide 

 

Please refer to APP quick start guide for more details 

Downloading the «Microlife Connected » App 

Download 

«Microlife Connected » App for free from Google   

Play™ (Android) or App Store (iOS) and install it on your smartphone.   

Setup User Profile 

 

1. Open the App and select “Start” to begin using the App.   

2. Select “Settings” on the navigation menu (bottom) to enter “My profile”.   

3. Edit profile information, then select “Save” to complete Profile setup.   

 

Transfer Data 

 

1. Turn on Bluetooth of Smartphone.   

2. Open the app on the Smartphone, and select the Temperature Overview interface.   

3. Make sure to FR1DQ1-B is within 5 meters of your Smartphone, and urn off other Bluetooth device if possible in case it 

interfere the data transfer. 

4. Turn on FR1DQ1-B in Body Temperature mode. Bluetooth of FR1DQ1-B is activated (when not taking measurement) and 

automatically searches for Smartphone to connect to. 

5. When FR1DQ1-B is connected to the App on a Smartphone, FR1DQ1-B will transfer data automatically if new data (hasn’t 

been transferred previously) is available, while transferring. The LCD of FR1DQ1-B will show new data with “-” and 3 digits 

thermometer designated ID for 3 seconds, no new measurement can be start within this 3 seconds. 

6. Upon data transfer, the App will display a message with “-” and 3 digits thermometer ID (MAC address) to confirm which 

Patient Log in the App the data should be assigned to. Be sure to check“-”and 3 digits thermometer ID is identical on 

FR1DQ1-B and APP then select the Patient Log and Confirm to complete the data transfer. 

 

  If“

”and 3 digits thermometer is not identical of both App and FR1DQ1-B, please discard the message show on the app to 

stop the data transfer, and record the temperature data into the App manually. Or take a new measurement and start Transfer Data 

from step 1 to 6 again. 

Summary of Contents for FR1DQ1-B

Page 1: ...FR1DQ1 B Infrared Forehead Thermometer Distributed by Microlife USA Inc 1617 Gulf to Bay Blvd Floor 2 Clearwater FL 33755 UNITED STATES Phone 727 442 5353 www microlifeusa com Made in China...

Page 2: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27...

Page 3: ...temperature too high 21 Ambient temperature too low 22 Error function display 23 Blank display 24 Flat battery 25 Date Time 26 Beeper function setting 27 Protective cap Read the instructions carefully...

Page 4: ...Connected Health APP The memory data can be transferred to the smart phone via Bluetooth Table of Contents 1 The Advantages of this Thermometer Measures in a matter of seconds Measurement with distanc...

Page 5: ...urface temperature in a baby s bottle Surface temperature of a baby s bath Accurate and reliable The unique probe assembly construction incorporates an advanced infrared sensor ensuring that each meas...

Page 6: ...re measurement the thermometer and the person whose temperature is to be measured should be in the room temperature for at least 30 minutes If the measurement result is not consistent with the patient...

Page 7: ...ice detect the distance is appropriate within 5cm the screen shows good 10 with 1 short beep then press START IO button 4 to start measuring For 1s mode when the device detects the distance is appropr...

Page 8: ...y mode directly If there is any item of time setting have not been completed they will be show with no information Setting the beeper 26 At any status press MODE 6 button for 3 seconds will enter beep...

Page 9: ...ify the completion of measurement 7 Read the recorded temperature from the LCD display 8 For the next measurement remove the thermometer from the forehead and wait until the C F icon is flashing Follo...

Page 10: ...s of age with a compromised immune system and for whom the presence or absence of fever is critical 2 When the user is learning how to use the thermometer for the first time until he she has familiari...

Page 11: ...enter My profile 3 Edit profile information then select Save to complete Profile setup Transfer Data 1 Turn on Bluetooth of Smartphone 2 Open the app on the Smartphone and select the Temperature Overv...

Page 12: ...ot be used to start or stop the thermometer nor update the firmware of thermometer via Bluetooth Wireless communication interference This product operates in an unlicensed ISM band at 2 4 GHz In the e...

Page 13: ...devices must be disposed of in accordance with the locally applicable regulations not with domestic waste 14 Guarantee This device is covered by 5 years guarantee from the date of purchase The guarant...

Page 14: ...5 40 0 C 41 104 0 F 15 95 relative maximum humidity Storing conditions 25 55 C 13 131 F 15 95 relative maximum Automatic Switch off Approx 30 sec when power on without measurement after measurement Ba...

Page 15: ...ation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interf...

Page 16: ...ronment guidance RFemissions CISPR 11 Group 1 The model FR1DQ1 B uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in n...

Page 17: ...l or hospital environment Surge IEC 61000 4 5 1 kV line s and neutral N A Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltag...

Page 18: ...he recommended separation distance calculated from the equation applicable to the frequency of the transmitter Conducted RF IEC 61000 4 6 3 Vrms 150 kHz to 80 MHz N A Recommended separation distance R...

Page 19: ...TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured...

Page 20: ...t power of transmitter Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 12 0 23 0 1 0 38 0 73 1 1 2 2 3 10 3 8 7 3 100 12 23 Fo...

Reviews: