21
aponorm
®
Mobil Plus
EN
Which batteries and which procedure?
2. Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
3. To set date and time, follow the procedure described in
«Section 2.».
)
The memory retains all values although date and time (and
possibly also set alarm times) must be reset – the year number
therefore flashes automatically after the batteries are
replaced.
)
Please use 2 new, long-life 1.5V, size AAA batteries.
Batteries flat – replacement
When the batteries are flat, the battery symbol
AO
will flash as soon
as the instrument is switched on (flat battery displayed). You cannot
take any further measurements and must replace the batteries.
1. Open the battery compartment
3
by pushing at the two arrows
by pulling off the cap.
Batteries almost flat
When the batteries are approximately ¾ used the battery symbol
AO
will flash as soon as the instrument is switched on (partly filled
battery displayed). Although the instrument will continue to measure
reliably, you should obtain replacement batteries.
7. Battery Indicator and Battery change
)
Do not use batteries beyond their date of expiry.
8.
8. Error Messages
If an error occurs during the measurement, the measurement is inter-
rupted and an error message, e.g. «
ERR 3
», is displayed.
Error
Description Potential cause and remedy
«
ERR 1
» Signal too
weak
The pulse signals on the cuff are too
weak. Re-position the cuff and repeat
the measurement.*
)
The batteries must be removed and recharged, if the battery
symbol (battery flat) appears! They must not remain inside the
instrument, as they may become damaged (total discharge as
a result of low use of the instrument, even when switched off).
)
Always remove the rechargeable batteries, if you do not
intend to use the instrument for a week or more!
)
The batteries can NOT be charged in the blood pressure
monitor! Recharge these batteries in an external charger and
observe the information regarding charging, care and dura-
bility!
Using rechargeable batteries
You can also operate this instrument using rechargeable batteries.
)
Please use only type «NiMH» reusable batteries!
)
Remove batteries, if the instrument is not going to be used
for a prolonged period.
9.
Summary of Contents for 47038
Page 25: ...25 aponorm Mobil Plus EN...
Page 49: ...49 aponorm Mobil Plus TR...
Page 51: ...51 aponorm Mobil Plus RU A A 1 2 3 4 5 a 5 6 6 7 8 9 10 11 7 8 9 10 11 11 2 o...
Page 52: ...52 aponorm by 1 x x x x x x x x x x...
Page 54: ...54 aponorm by 150 85 120 98 N P 2 3 3 M 5 Time 6 M time Time time 3...
Page 55: ...55 aponorm Mobil Plus RU 13 5 21 5 5 25 8 5 1 AN 7 8 9 4 AM O 1...
Page 56: ...56 aponorm by N P 17 M M 200 5 M 5 N P AL 6 k F i h i 0 0 a g av g 6 5 AL 6 1 k a x k 5...
Page 58: ...58 aponorm by AO 3 7 U AO X 1 X X NNiMHP 2 1 5 AAA O 2 Q 8...
Page 59: ...59 aponorm Mobil Plus RU N P N P N P 300 200 5 N P 40 8 N P N P N P 9...
Page 60: ...60 aponorm by x x x x x x x N 1 P 9 x x N P x 10...
Page 62: ...62 aponorm by S5 2 x 1 5 AAA 93 42 EEC NIBP EN 1060 1 3 4 ANSI AAMI SP10 40 200 O 0 299 1 S 3...
Page 63: ...63 aponorm Mobil Plus RU...