A final module screen is displayed showing which specific modules that were initialised.
The controller then displays the lamp optimisation screen for 60 seconds to allow
the lamp to reach its optimum output. Finally, a final “start-up complete” screen is
displayed. The system will now be ready to disinfect water flow.
all detected modules
lamp reaching max output
successful start-up
UVCXS/MCXS Operational Screens
On systems without the UV monitor, the default screen shows the
Microlene Home
Screen
. At any point during operation the user is able to scroll through the
Microlene
Home Screen, Lamp life remaining
,
QR Code, Contact Info and Maintenance
Parts
screens by pressing the button located on the front of the controller.
On systems with the UV monitor, the system will display the same screens except the
UV Intensity replaces the home screen. The UV Intensity screen displays the level of
UV light detected by the sensor. UV intensity can be affected by poor water quality,
scaling on the quartz sleeve and/or sensor, lamp failure or lamp expiring. The following
screens show the UV Intensity dropping.
Below 56%, the numbers and warning sign turn red and an audible chirp is given
by the ballast every 15 seconds. Below 51%, the screen is solid red and a constant
audible alarm is given. This alternates with a screen indicating “water may be unsafe
for consumption”. If you have the solenoid module (optional purchased separately,
also only works if using with upgraded Controllers MCXS-CONT or UVCXS-CONT)
the controller de-activates the solenoid valve, shutting off all water flow.