2

 

 

The device should only be used with rate voltage and frequency. Make sure that the available voltage is not higher than 120V as 
stated at the end of this manual. 

Make sure the power cord is never crimped or damaged in any way, as this could cause shock and damage. If your power chord is 
damaged in any way, please purchase a new cable from your local MICROH dealer. Always disconnect power, when the device is 
not in use or before cleaning it. Never pull out the plug by tugging the power cord.  

During initial start-up, some smoke or smell may arise. This is a normal process, and does not necessarily mean that the device is 
defective. It should decrease gradually. Please do not project the beam onto combustible substances. 

Fixtures cannot be installed on or near combustible substances. Keep more than 50cm distance from wall for proper ventilation and 
air flow. If your fixture is or has become damaged in any way, it shall be exclusively replaced or repaired by the manufacturer to 
avoid any hazard. 

 

 

 

 

3. OPERATION INSTRUCTIONS 

 

- Do not turn on the fixture if it has been through severe temperature differences. Damage may occur to the fixture. Wait 
until unit is at room temperature to operate.  

- The unit should be protected from any tremor or agitation during transport.  

- Do not expose the fixture in any excessive heat, moisture or any environment with too much dust when installing. Do not 
lay any power cables on the floor. It may cause electronic shock or damage to persons or equipment. 

- Make sure to attach the safety chain and ensure the screws are properly screwed in when installing the fixture. 

- Make sure the lens is in good condition. It is recommended to replace the unit if there are any damages or severe 
scratches. 

- Make sure the fixture is operated and installed by qualified personnel. 

- Keep the original packaging in case of defective product. 

- Any non-manufacturer additions, modifications or changes in any way will void all warranty. 

- Please do not attempt to open unit. It is only to be serviced by an authorized technician. If this occurs, or is apparent, the 
warranty will be voided. 

- The fixture’s warranty will be voided if there are any malfunctions from not following the user manual or any illegal 
operation (shock short circuit, electronic shock, lamp broke, etc.)   

Summary of Contents for LED SLIM P64

Page 1: ......

Page 2: ......

Page 3: ...is fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The MICROH LED SLIM P64 wash fixture uses 181 x 10mm LED s 36 red 85 green 60 blue which feature high brightness and stability Please carefully unpack it when you receive the fixture and check if it was damaged during the transportation And please check whether the following items are inc...

Page 4: ...urn on the fixture if it has been through severe temperature differences Damage may occur to the fixture Wait until unit is at room temperature to operate The unit should be protected from any tremor or agitation during transport Do not expose the fixture in any excessive heat moisture or any environment with too much dust when installing Do not lay any power cables on the floor It may cause elect...

Page 5: ...t is in 4 channel mode C H 6 means it is in 6 channel mode Without connecting the DMX controller the display will flicker and blackout 4 MOUNTING AND INSTALLATION Caution For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installati...

Page 6: ...sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 5 DMX 512 CONTROL CONNECTIONS This fixture complies with international USITT DMX standards and can be used with either a 3 pin or 5 pin DMX connector Plug in the provided 3 pin XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR in...

Page 7: ... of the last fixture in the chain Please see illustrations below 6 PHOTOMETRIC DATA 7 DMX CHANNELS DMX mode 1 4 channels CHANNEL VALUE FUNCTION CH1 000 189 DIMMER dim bright 190 250 FLASH slow fast 251 255 NO FUNCTION CH2 000 255 RED dim bright CH3 000 255 GREEN dim bright CH4 000 255 BLUE dim bright 1 2 3 PIN 3 PIN 2 120Ω ...

Page 8: ...s between 0 189 will control the dimmer values between 190 250 will control flash speed values between 251 255 will have no function When using Channel 5 values between 0 31 Channel 2 3 and 4 will control RED GREEN BLUE colour dimmer Channel 1 values between 0 189 will control the dimmer values between 190 250 will control flash speed values between 251 255 will have no function 8 KEY FEATURES 181...

Page 9: ... 85 Blue 60 OPERATING TEMPERATURE 25 C to 45 C VOLTAGE 120VAC 60Hz FUSE 1A 125V GMA MAX 30W DIMENSIONS 8 75 x 2 5 x 11 222 x 64 x 279mm PACKING DIMENSIONS 13 5 x 12 5 x 6 75 343 x 318 x 171 mm NET WEIGHT 4 85 lbs 2 2 kg GROSS WEIGHT 6 95 lbs 3 15 kg WARRANTY 2 Year Limited Warranty ...

Page 10: ...o accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition and prevent from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the...