Microh LED Quadpar TRI MKII User Manual Download Page 8

 

6. PHOTOMETRIC DATA 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LED Quadpar TRI MKII

Page 1: ......

Page 2: ...uminum casing The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The MICROH LED QUADPAR TRI MKII wash fixture uses 436 powerful 10mm LED s 109 per head 20 Red 52 Green 37 Blue swhich feature high brightness and ...

Page 3: ...ive It should decrease gradually Please do not project the beam onto combustible substances Fixtures cannot be installed on or near combustible substances Keep more than 50cm distance from wall for proper ventilation and air flow If your fixture is or has become damaged in any way it shall be exclusively replaced or repaired by the manufacturer to avoid any hazard 3 OPERATION INSTRUCTIONS Do not t...

Page 4: ...n the program in the designed order by cycle 2 When press the FREEZE foot pedal the fixture will lock the current condition Press the FREEZE foot pedal again and the fixture will continue running the previous program you have select 3 When the fixture is in the foot pedal controller function the LED digital display will show the current running program MANUAL COLOUR DIMMING MODE Press MODE button ...

Page 5: ...and pressing and buttons to adjust sensitivity level MANUAL COLOUR DIMMING MODE Press R G B to choose program mode and press and buttons to adjust the intensity of the light Press FLASH to turn on off flash effect pressing and buttons to adjust the flash speed DMX MODE There are seven DMX modes 2 3 4 7 8 14 or 15 Channels You must set the DMX Channel mode before you address the fixture To select y...

Page 6: ...ation etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting Points Overhead mounting requires extensive experience including calculating working load limits A knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture are all imperat...

Page 7: ...together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor co...

Page 8: ...7 6 PHOTOMETRIC DATA ...

Page 9: ...8 7 MENU NAVIGATION ...

Page 10: ...H2 000 255 Red dim bright CH3 000 255 Green dim bright CH4 000 255 Blue dim bright DMX mode 3 8 channel mode CH No DMX value Function CH1 000 255 Master dimmer dim bright CH2 000 No function 001 255 Strobe slow fast CH3 000 255 Red panel 1 2 dim bright CH4 000 255 Green panel 1 2 dim bright CH5 000 255 Blue panel 1 2 dim bright CH6 000 255 Red panel 3 4 dim bright CH7 000 255 Green panel 3 4 dim b...

Page 11: ...een panel 1 dim bright CH5 000 255 Blue panel 1 dim bright CH6 000 255 Red panel 2 dim bright CH7 000 255 Green panel 2 dim bright CH8 000 255 Blue panel 2 dim bright CH9 000 255 Red panel 3 dim bright CH10 000 255 Green panel 3 dim bright CH11 000 255 Blue panel 3 dim bright CH12 000 255 Red panel 4 dim bright CH13 000 255 Green panel 4 dim bright CH14 000 255 Blue panel 4 dim bright ...

Page 12: ...gram 2 speed 0 stop 1 255 into99 grade 1 2 is grade 1 more than 247 is grade 99 slow fast 108 119 program 3 120 131 program 4 132 143 program 5 144 155 program 6 156 167 program 7 168 179 program 8 180 191 program 9 192 203 program 10 204 215 program 11 216 227 program 12 228 239 auto run 240 255 sound active Sound sensitive 0 OFF 1 255 into 31grade ...

Page 13: ...anel 2 Green panel 2 Blue panel 2 Red panel 3 Green panel 3 Blue panel 3 Red panel 4 Green panel 4 Blue panel 4 10 249 auto run speed 0 stop 1 255 into 99 grade 1 2 is 1 grade more than 247 is 99 grade Slow fast No use No use No use No use No use No use No use No use No use No use No use 250 255 sound active Sound sensitiv ity 0 OFF 1 255 into 31 grade No use No use No use No use No use No use No ...

Page 14: ... yellow 36 47 green 48 59 cyan 60 71 blue 72 83 purple 84 95 white 96 107 program 2 speed 0 stop 1 255 into99 grade 1 2 is grade 1 more than 247 is grade 99 slow fast 108 119 program 3 120 131 program 4 132 143 program 5 144 155 program 6 156 167 program 7 168 179 program 8 180 191 program 9 192 203 program 10 204 215 program 11 216 227 program 12 228 239 auto run 240 255 sound active Sensitivity ...

Page 15: ...DQUADPAR REMOTE Digital Display 10 TECHNICAL SPECIFICATIONS MODEL LED QUADPAR TRI MKII LAMP 28 Tri LEDS Per Head 7 VOLTAGE 120VAC 60Hz 180W FUSE 120VAC 1 5A DIMENSIONS W x H 47 2 x 94 5 Max Height 9 8 120 x 240 cm Max Height 3m CASE DIMENSIONS lL x W x H 29 x 14 x 7 5 Max Height 9 8 737 x 356 x 191 mm NET WEIGHT 20 5 lbs 9 3 kg WARRANTY 2 Year Limited Warranty ...

Page 16: ...o accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approved technician every three months is advised Ensure the circuit contacts are in good condition and prevent from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the...

Page 17: ......