background image

 

This mode allows for multiple units slave fixtures to follow a single master fixture. 

1) Set the master fixture to one of the standalone operating modes: automatic, sound, user mode or static color modes 

2) For slave units, entered the Master/Slave mode, select "Slave", press Enter.

 

 

DMX VALUES 

3 Channels Mode: 

 

CHANNEL 

VALUE 

FUNCTION 

000-255 

Red: 0% ~ 100% 

000-255 

Green: 0% ~ 100% 

000-255 

Blue: 0% ~ 100% 

 

 

 

5 Channels Mode: 

 

CHANNEL 

VALUE 

FUNCTION 

000-255 

Red: 0% ~ 100% 

000-255 

Green: 0% ~ 100% 

000-255 

Blue: 0% ~ 100% 

000-255 

Master Dimmer 0% ~ 100% 

000-009 

No function 

010-255 

Strobe : Slow ~ Fast(1~30Hz) 

 

9 Channels Mode: 

 

 

CHANNEL 

VALUE 

FUNCTION 

 

 

000-255 

Red 0% ~ 100% 

 

 

Warm white 0% ~ 100% 

When values 169-208 in   

CH. 9 are activated 

000-255 

Green 0% ~ 100% 

 

 

Cool white 0% ~ 100% 

When values 169-208 in   

CH. 9 are activated 

000-255 

Blue 0% ~ 100% 

 

 

000-255 

Master Dimmer 0% ~ 100% 

 

 

000-009 

No function 

 

 

010-255 

Strobe : Slow ~ Fast(1~30Hz) 

 

 

000-019 

No Function 

 

 

020-039 

RED 100% / GREEN 0% ~ 100% / BLUE 0% 

 

 

040-059 

RED 100%    ~ 0% / GREEN 100% / BLUE 0% 

 

 

060-079 

RED 0% / GREEN 100% / BLUE 0% ~ 100% 

 

 

080-099 

RED 0% / GREEN 100%    ~ 0% / BLUE 100% 

 

 

100-119 

RED    0% ~ 100% / GREEN 0% / BLUE 100% 

 

 

120-139 

RED 100% / GREEN 0% / BLUE 100%    ~ 0% 

 

 

140-159 

RED 100% / GREEN 0%    ~100%    / BLUE 0%~100% 

 

 

160-179 

RED 100%~ 0% / GREEN 100%    ~ 0% / BLUE 100% 

 

 

180-199 

RED 100% / GREEN 100% / BLUE 100% 

 

 

200-204 

White Color Temprature 1 

WARM 

205-209 

White Color Temprature 2 

 

Summary of Contents for LED NOVA 4

Page 1: ...LED NOVA 4 USER MANUAL For safety please read this user manual carefully before initially use Package Included LED NOVA 4 User Manual Power Input Cord 5mm Allen Key Safety Instructions...

Page 2: ...to the maximum 4 devices at 120 VAC or 8 at 230 VAC DO NOT exceed this number DMX Linking Connection This device can work with a DMX controller using a regular DMX serial connection This device uses...

Page 3: ...or To set user mode intensity of R G B separately for color mixing and strobe rate 7 Auto Program To set built in automatic programs Pr 01 Pr 10 and speeds 000 100 8 Master Slave To set Master Slave m...

Page 4: ...the device to run strobe desired Entered user mode Manual color use UP and DOWN to select the R G B for Colors intensity or S for strobe Use UP and DOWN to set the colors intensity values 0 255 or St...

Page 5: ...5 Strobe Slow Fast 1 30Hz 9 Channels Mode CHANNEL VALUE FUNCTION 1 000 255 Red 0 100 Warm white 0 100 When values 169 208 in CH 9 are activated 2 000 255 Green 0 100 Cool white 0 100 When values 169 2...

Page 6: ...g 129 152 Auto Program PR 06 Chase 1 153 176 Auto Program PR 07 Chase 2 177 200 Auto Program PR 08 Chase 3 201 224 Auto Program PR 09 Chase 4 225 248 Auto Program PR 10 Loop above pr 01 pr 09 249 255...

Page 7: ...ogram PR 04 7 colors Fading 105 128 Auto Program PR 05 Color Macros Fading 129 152 Auto Program PR 06 Chase 1 153 176 Auto Program PR 07 Chase 2 177 200 Auto Program PR 08 Chase 3 201 224 Auto Program...

Page 8: ...depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Replacing the fuse If the fine wire fuse of the device fuses only repl...

Reviews: