This mode allows for multiple units slave fixtures to follow a single master fixture.
1) Set the master fixture to one of the standalone operating modes: automatic, sound, user mode or static color modes
2) For slave units, entered the Master/Slave mode, select "Slave", press Enter.
DMX VALUES
3 Channels Mode:
CHANNEL
VALUE
FUNCTION
1
000-255
Red: 0% ~ 100%
2
000-255
Green: 0% ~ 100%
3
000-255
Blue: 0% ~ 100%
5 Channels Mode:
CHANNEL
VALUE
FUNCTION
1
000-255
Red: 0% ~ 100%
2
000-255
Green: 0% ~ 100%
3
000-255
Blue: 0% ~ 100%
4
000-255
Master Dimmer 0% ~ 100%
5
000-009
No function
010-255
Strobe : Slow ~ Fast(1~30Hz)
9 Channels Mode:
CHANNEL
VALUE
FUNCTION
1
000-255
Red 0% ~ 100%
Warm white 0% ~ 100%
When values 169-208 in
CH. 9 are activated
2
000-255
Green 0% ~ 100%
Cool white 0% ~ 100%
When values 169-208 in
CH. 9 are activated
3
000-255
Blue 0% ~ 100%
4
000-255
Master Dimmer 0% ~ 100%
5
000-009
No function
010-255
Strobe : Slow ~ Fast(1~30Hz)
6
000-019
No Function
020-039
RED 100% / GREEN 0% ~ 100% / BLUE 0%
040-059
RED 100% ~ 0% / GREEN 100% / BLUE 0%
060-079
RED 0% / GREEN 100% / BLUE 0% ~ 100%
080-099
RED 0% / GREEN 100% ~ 0% / BLUE 100%
100-119
RED 0% ~ 100% / GREEN 0% / BLUE 100%
120-139
RED 100% / GREEN 0% / BLUE 100% ~ 0%
140-159
RED 100% / GREEN 0% ~100% / BLUE 0%~100%
160-179
RED 100%~ 0% / GREEN 100% ~ 0% / BLUE 100%
180-199
RED 100% / GREEN 100% / BLUE 100%
200-204
White Color Temprature 1
WARM
205-209
White Color Temprature 2