Series 3600
6
Microframe Corporation
1.800.635.3811
To change the programmable options on the display, you must transmit special codes to the display. These
special codes are described below.
How to Change a Programmable Option Using the Multi-Number MultiPage Transmitter
Press [*] to get to the Pager prompt. Type 9999 [ENTER]. At the Beep Type prompt press [ENTER]. At the
Message prompt, type the area to change as a two-digit number. Add a space using the [SETUP] key. Then
type the value to set as a two-digit number. Press [SEND] to set the display option.
As an example we will change the Display Rollover Time to 1 second per number. The message format will be
“01_01”. To begin, press [*] “9999” [ENTER]. Skip the Beep Type prompt by pressing [ENTER]. At the
M
essage prompt type in “01” [SETUP] “01” [SEND]. The transmitter will show it is sending the message. The
display will reflect the change by immediately changing the delay between numbers to one second.
The following user-programmable display options can be changed using the Multi-Number MultiPage
Transmitter:
0
– Number Source
1
– Rollover
2
– Auto-delete
3
– Chime
4
– Slow Flash
5
– Fast Flash
0 Setting the Display Number Source
Set area 00 to a value of 0000-9999. If the value is non-zero, the display will listen for that pager number and
show the message. Otherwise, it will show the pager number paged. The default is to listen for messages
(numbers) on pager 1500.
1 Setting the Display Rollover Time
Set area 01 to any value from 00-09. Each unit is 1 second. The default is 3 seconds (03). 00 means the
display will only show the last number received (no rollover).
2 Setting the Display Auto-Delete Time
Set area 02 to any value from 00-42. Each unit is 1 minute. The default is 42 minutes (42). 00 means the
auto-delete is disabled.
3 Setting the Display Chime Duration
Set area 03 to any value from 00-99. Each unit is 0.1 seconds. The default is 0.3 seconds (03). 00 means the
chime is disabled.
4 Setting the Display Slow-Flash Time
Set area 04 to any value from 00-99. Each unit is 10 seconds. The default is 90 seconds (09)
– 1.5 minutes.
00 disables the slow-flash function.
5 Setting the Display Fast-Flash Time
Set area 05 to any value from 00-99. Each unit is 10 seconds. The default is 180 seconds (18)
– 3 minutes.
00 disables the fast-flash function.
CLEARING THE DISPLAY
Setting area 99 to a value of 98 will clear all numbers from the Visual-Pager® display.
RESETTING DISPLAY TO FACTORY DEFAULTS
Setting area 99 to a value of 99 will reset all program areas to factory defaults.
Visual-Pager® Display Programming Instructions