4  GEO PULSAR USER GUIDE

4.1 TURNING ON THE PAGER

Hold down the “LARGE BLACK BUTTON”

until the pager comes on.

4.2 SENDING A NUMERIC MESSAGE

To send a numeric message to a pager,

simply enter the pager number followed by the
“ENTER” key. The transmitter screen will
display “BEEP TYPE.”  Simply press “ENTER”
to bypass this. The transmitter screen will then
display “ENTER MESSAGE.” Using the num-
ber keys, enter up to a 12-digit numeric mes-
sage followed by the “SEND” key.  Note: Since
a numeric message is entered after the “BEEP
TYPE,”(pre-defined message) prompt, the alpha
message selected will be ignored.

4.3 RECEIVING A PAGE

The Geo Pulsar will start to vibrate when it

is paged. No action is necessary on the receiv-
ing end at this point. The pager will stop
vibrating after approximately 8 seconds. If the
user would like to stop the vibration before the
8 seconds, simply press the “LARGE BLACK
BUTTON.” If a numeric message is sent to the
pager, the message will be visible on the pager
screen until the pager stops vibrating. To view
the message after the pager has stopped vibrat-
ing, press the “LARGE BLACK BUTTON” once.

4.4 SENDING A GROUP CALL PAGE

All pagers respond to call number “900”

(unless another group call number has been
chosen).  To page all pagers at once, simply
enter “900” and “SEND.”

4.5 MANUAL PAGER TURN-OFF

Press the “RIGHT ARROW BUTTON.”  The

words “PGR OFF” will appear on the LCD
screen. Press the “LARGE BLACK BUTTON”
once to confirm.   NOTE:  If you have chosen to
disable the pagers’ on/off button, the pagers can
only be turned off from the transmitter.

4.6 PAGER TURN-OFF FROM BASE

Enter the pager number followed by the

“ENTER” key.  Press “ENTER” again to bypass
“BEEP TYPE” screen.  When screen reads
“ENTER MESSAGE,” enter the message code
“((123456” followed by “SEND.”

Note: Since all pagers respond to call num-

ber “900,” paging “900” with the message code
“((123456” will turn all pagers off.

4.7 POWER CHECKING

When the battery level is low, a low-battery

symbol will appear at the bottom of the pager
screen.

4.8 LIGHTING FUNCTION

Pressing the “LEFT ARROW BUTTON” for

one second can turn on the backlight on the
LCD screen. The light will shut off automati-
cally after approximately 10 seconds; or the
user may turn the light off manually by press-
ing the “LEFT ARROW” once.

4.9 CAUTION

a)

The pager is made up of LCD and
precision elements. Avoid water and
high temperature.

b)

Remove the battery if the pager will not
be in use for a long period of time.

c)

If the pager is not working properly, do
not dismantle or repair it yourself.

Summary of Contents for SERIES 3002

Page 1: ...Microframe Corporation Series 3002 DataPage II w Line Port Interface Operating Manual B3002 7011 B3002 7011 ...

Page 2: ......

Page 3: ...STALLATION SPECIFICATION GUIDE ITEM NO A3002 7011 REVISION DATE 04 02 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Page 4: ...or warranty service please contact Microframe at 1 800 635 3811 A tech will gladly assist you Assistance For any product assistance or maintenance help contactMicroframebyeithercalling1 800 635 3811or emailing us at support microframecorp com Safety Do not install substitute parts or perform any modi fication to the product without first contacting Microframe Warning All power transformers line co...

Page 5: ...HA MESSAGE 9 2 6 PAGER TURN OFF FROM BASE 9 2 7 TURNING OFF ALL PAGERS 9 2 8 INDIVIDUAL PAGER TURN OFF 9 2 9 ADVANCED FEATURES 9 2 10 SPEED DIALING 10 2 11 TONE ONLY PAGING 10 3 SYSTEM OVERVIEW 11 3 1 PERFORMANCE 11 3 2 RANGE EXPANSION 11 3 3 FACTORY PROGRAMMING 11 3 4 OVERVIEW 11 4 GEO PULSAR USER GUIDE 13 4 1 TURNING ON THE PAGER 13 4 2 SENDING A NUMERIC MESSAGE 13 4 3 RECEIVING A PAGE 13 4 4 SE...

Page 6: ...ager Microframe can pro grampre definedalphamessagestoenhancecommuni cation between the sender and receiver Up to 874 total charactersmaybeused makingitpossibletoprogramas manydifferentmessagesasyouwantwithinthatcharac ter limit Every space counts as a character as does every line For example you could pre define 45 mes sages that are 2 5 words in length or 70 two word messages Allpre definedmessa...

Page 7: ...d mounting the transmitter in the im mediate vicinity of telephones exchanges or computer equipment A few feet can make the 1 1 CONNECTING THE ANTENNA Connect the 90 degree aerial to the BNC connector bayonet twist lock located at the side of the transmitter Slide the plastic cover over the connector engaging the two lugs into the corresponding recesses in the side of the case Thiswillmaintainthea...

Page 8: ...re thoughtpriortoinstallation coupledwithafewtests can normally avoid most problems 1 5 DRY CONTACTS There are two volt free dry contacts available for use with either Normally Open Normally Closed or Change of State switches When either is triggered the pro grammedmessage s willbesenttotheselectedpager or group of pagers When used in the Normally Open mode only themessagewillrepeatwhileintheactiv...

Page 9: ...thin the pager itself From a phone within your PBX system dial the extension or line port that the DataPage II is attached to You will hear a three tone sign 2 OPERATION on threenotesescalatinglowtohigh Dialthe pager number then press or see note Wait for acceptance tone single mid tone or pro ceed To send one of the pre defined messages from the table supplied dial followed by the message number ...

Page 10: ...past the inactivity timer which effectively means that the sign on tones will never be received 2 10SPEEDDIALING It may be possible to effect some speed dial functions with your telephone system however telephone ex changes vary as to the way in which they perform dependingupontheirowninternalprotocol Withcertain systems you may have to establish an audio connection with the port prior to sending ...

Page 11: ...irements High frequencies can equate to high power losses Always use the best quality cable RG58 is only acceptable on cable runs of up to 5 meters We recommend RG213 or equivalent on greater lengths If in doubt consult your dealer Co axial cable intended for TV satellite or CCTV installationsisnormally75ohm andtherefore totally unsuitable and can cause severe trans mitter damage Subject to licens...

Page 12: ...F This interface is only intended for use with systems dedicated to two wire ports Access is gained by dialing the extension number The ringing will alert the DataPagewhichwillpickuptheline Useofthisinterface with hybrids of any sort is not recommended and we cannot provide any support for such applications Both of these interfaces contain line voltage isolation devices There is total electrical i...

Page 13: ...NDING A GROUP CALL PAGE All pagers respond to call number 900 unless another group call number has been chosen To page all pagers at once simply enter 900 and SEND 4 5 MANUAL PAGER TURN OFF Pressthe RIGHTARROWBUTTON The words PGR OFF will appear on the LCD screen Press the LARGE BLACK BUTTON once to confirm NOTE If you have chosen to disablethepagers on offbutton thepagerscan only be turned off fr...