Microframe Corporation
8
604 South 12
th
Street
Broken Arrow, OK 74012
800-635-3811
www.microframecorp.com
Series 900
904\ax\9703.ai
PO box 1700 Broken Arrow, Ok 74013
Disconnect power before replacing
1.5 Amp AGC fast blow fuse
under bottom
WARNING
ELECTRICAL DEVICE
KEEP OUT OF THE REACH OF CHILDREN
.
A
/C
G
N
D
S
IG
1 1/2 AMP
FAST BLO
A
/C
1 1/2 AMP
FAST BLO
A
/C
G
N
D
S
IG
1 1/2 AMP
F
AST BLO
B
L
A
C
K
1 1/2 AMP
FAST BLO
R
E
D
BLACK
1 1/2"
1/4"
B
L
A
C
K
R
E
D
B
L
A
C
K
R
E
D
S
IG
G
N
D
1 1/2 AMP
FAST BLO
Ty-Wrap
NOTCH
1/8" SLOTTED
SCREWDRIVER
A
/C
G
N
D
G
N
D
S
IG
S
IG
RED
DISPL AY
A
U
X
A
U
X
A
U
X
A
U
X
NEX T DISPL AY
ORKEY PAD
STEP 1:
Remove slide-on cover from
back of keypad.
STEP 2:
Remove 1.5” of gray jacket
from wire and separate the
internal wires. Strip 1/4” of
insulation from each wire and
pre-form as shown.
STEP 3:
Insert black wire into one of
the GND terminals.
Insert red wire into one of the
SIG terminals.
Tighten terminal screws.
STEP 4 (IF REQUIRED):
If a second set of wires are
required at the keypad, repeat
Step 3 being careful not to
reverse the SIG and GND
connections.
STEP 5:
Install slide-on cover being
careful to first form wires so
the Ty-Wrap is inside the case
as shown. The slide-on cover
has a notch for the wires to fit
through.
TO NEXT DISPLAY OR KEYPAD
TO DISPLAY
Connecting a Visual-Pager® Display to a Keypad