Microframe Corporation 910 Installation And Specification Manual Download Page 10

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

10

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 900 

 

 

ENTERING OPTIONS MODE 
To enter the Options Mode, do the following: 

1) Turn on Keypad. 
2) During the startup screen, press ‘0’. 
3) “System Options” will display, signifying you are in options mode. 

 
OPTIONS TABLE SUMMARY 
General Options 

 

 

 

Advanced Options 

Rollover   

#11 

 

 

MastSlave 

#21 

AutoDel   

#12 

 

 

EntryAuto #22 

KeyBeep  #13 

 

 

Sort List   

#23 

Chime 

 

#14 

 

 

Duplicates 

#24 

Fact Reset 

#19 

 

 

DeleteKey 

#25 

 

 

 

 

 

Address   

#26 

 

 

 

 

 

Keypad Type 

#27 

NAVIGATION 
Type the two-digit number for the option you wish to set.  The current value is shown.  Type a new number to change the value.  
Press [ENTER] to save or [DELETE] to cancel. 
 
Option 

 

 

Option Number 

 
 
 
 
 
 
Value 

 

 

Range 

 
 
OPTIONS DEFINITIONS 
#11  Rollover 

0-9 Seconds; Default 3 
Rollover is the length of time a number is shown on the Visual-Pager® display before advancing to the next number in 
the list.  A value of 0 means each number will be displayed until it is deleted. 

#12  AutoDel 

0-21 Minutes; Default 0 
Autodelete is the time the keypad will hold a number before automatically deleting it.  A value of 0 means autodelete is 
disabled. 

#13  KeyBeep 

0-1 Off/On; Default 1 
The audible feedback sound can be enabled or disabled. 

#14  Chime 

0.0-9.9 Seconds; Default 0.3 
Sets the Visual-Pager® display chime duration.  Not all displays follow this option. 

#19  Factory Reset 

0-1 No/Yes;  
Resets all options to factory defaults. 

#21  MastSlave 

0-2 Auto/Master/Slave; Default 0 
This controls the master/slave arbitration on a system.  There should only be one master on a system.   

Auto – Allows the keypads to negotiate which one is the master.   
Master – The Keypad will always be a master.   
Slave – The Keypad will always be a slave. 

#22  Entry, Auto 

0-4 None/Enter/Delete/Y/N; Default 3 
This option determines number entry behavior.  This can be used to set up dedicated quick-entry 
keypads for enter and delete. 

None – No response to numbers typed unless user first presses [ENTER] or [DELETE]. 
Enter,N – When user types a number, keypad assumes Enter Mode.  When user has typed all 6 
digits, waits for [ENTER] to be pushed before adding number. 
Delete,N – When user types a number, keypad assumes Delete Mode.  When user has typed all 
6 digits, waits for [DELETE] key to be pushed before deleting number. 
Enter,Y – When user types a number, keypad assumes Enter Mode.  When user has typed all 6 
digits, automatically adds number. 
Delete,Y – When user types a number, keypad assumes Delete Mode.  When user has typed all 
6 digits, automatically deletes number. 

Keypad Options

 

Summary of Contents for 910

Page 1: ... Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 900 INSTALLATION and SPECIFICATION GUIDE Manual No D0910 7010 Revision Date 09 2013 Control 1 6 D0910 7010 ...

Page 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Page 3: ...pecificationGuide Table of Contents Series 900 System Overview and Features 4 System Installation Instructions 5 Maximum Cable Wire Length Chart 6 How to Connect Multiple Keypads to a Display 7 How to Connect a Display to a Keypad 8 Keypad Operation 9 Keypad Options 10 Visual Pager Display Operation 11 Error Codes and Troubleshooting Chart 12 ...

Page 4: ...e Rollover Time Automatic Delete and Manual Advance Once a number is entered into the Keypad the number is sent immediately to the Visual Pager Display The keypad will store up to 32 numbers and display them sequentially until the operator deletes them In 4 digit mode the keypad will show numbers from 0 to 9999 This mode is compatible with Model 920 930 and 940 displays In 6 digit mode the keypad ...

Page 5: ...ounted at eye level However it may also be placed on a desk Multiple keypads may be used on the same system and will automatically communicate with each other when wired together KEYPAD CONNECTION Unplug the keypad before continuing Slide off the back cover of the keypad and connect the 2 conductor wire Connect the black wire to GND and the red wire to SIG There are two terminals for both GND and ...

Page 6: ...ly use 16 AWG wire from the keypad You can now install four Model 960 6 digit displays up to 1 200 feet from the keypad The TOTAL CABLE LENGTH sum of length of all cables in the system should not exceed 10 000 feet Maximum Cable Wire Distance in Feet Model 920 Model 930 Model 940 Model 960 Number of Displays 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 18 AWG 16 AWG 1 2000 2000 2000 2000 2000 2000 20...

Page 7: ...ELETE when the number is being displa yed 2 Ready123456 115 TO 24 VAC WALL MOUNTED TRANSFORMER Model 906 Model 910 K eypad ENTER 0 DELETE 1 3 4 5 6 7 8 9 Visual P ager Series 900 To ENTER a paging n umber type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a n umber is being entered To DELETE a paging n umber press DELETE when the number is being displa yed...

Page 8: ...Y AUX AUX AUX AUX NEX T DISPL AY ORKEY PAD STEP 1 Remove slide on cover from back of keypad STEP 2 Remove 1 5 of gray jacket from wire and separate the internal wires Strip 1 4 of insulation from each wire and pre form as shown STEP 3 Insert black wire into one of the GND terminals Insert red wire into one of the SIG terminals Tighten terminal screws STEP 4 IF REQUIRED If a second set of wires are...

Page 9: ...deleted DELETE MODE To delete a number press DELETE twice when that number appears on the keypad display The next available number will be displayed immediately You may also delete a number by pressing DELETE typing the number and pressing DELETE again If you make an error while deleting a number press ENTER MULTIPLE OUTPUTS The keypad will power multiple Visual Pager displays Please see the Maxim...

Page 10: ...ff On Default 1 The audible feedback sound can be enabled or disabled 14 Chime 0 0 9 9 Seconds Default 0 3 Sets the Visual Pager display chime duration Not all displays follow this option 19 Factory Reset 0 1 No Yes Resets all options to factory defaults 21 MastSlave 0 2 Auto Master Slave Default 0 This controls the master slave arbitration on a system There should only be one master on a system A...

Page 11: ...to 6 digit numbers Compatible with Model 960 Displays HYMNBOARD MODE If the user would like to use the keypad to show hymn numbers in a song service the following steps should be taken 1 Program the Rollover Time 1 1 to 0 2 Program the Sort Option 2 3 to 0 3 Program the DeleteKey Option to 2 After these options have been programmed enter the hymn numbers in the order in which they will be displaye...

Page 12: ... Keypad cannot remember settings Keypad is damaged Return for service Keypad displays CommErr Communication error Verify programming to make sure only one keypad is a master Check wiring between keypads Check for strong interference next to signal cable Keypad works but does not light up or has erratic numbers Poor signal connection to display Does the keypad work when connected to the display wit...