background image

Microframe Corporation

Series 3007 - DataPage Lite Transmitter

7

1  INSTALLATION PROCEDURES

Figure 1: Connecting the Antenna and Locking Cover

1.1 CONNECTING THE ANTENNA

Connect the 90 degree antenna to the BNC

connector located at the side of the transmitter.

Slide the plastic cover over the connector,

engaging the two lugs into the corresponding

recesses in the side of the case. This will

maintain the antenna in an upright position,

which is important for optimizing the range of

the transmitter (See Figure 1).

1.2 CONNECTING POWER SUPPLY

Connect the AC adapter power lead to the

power socket located at the far right-hand rear

corner of the base station (See Figure 2).

Plug the power supply into a convenient

wall socket and turn on the power.  When the

unit is first powered up, the system will display

the following screen for a few seconds:

DATAPAGE

LITE

Followed by:

PAGER: (1-9999)

                   >

The flashing cursor invites you to enter a

pager number (this can be any number between

1 and 9,999) after which you must press SEND

to transmit a page. See "Operation" for further

transmitting procedures.

IMPORTANT NOTE:

 Use only the power supply included with
your system!  The use of non-approved
power supplies will invalidate all war-
ranty and service.We also recommend
using a surge suppressor for protection.
Power surges are not covered under the
warranty.

1.3 PRECAUTIONS

Avoid mounting the transmitter in the im-

mediate vicinity of telephones, exchanges or

computer equipment. A few feet can make a

world of difference in avoiding interference

from the radio frequency generated by the

transmitter.

The performance of your system will be

affected by: foil backed wallboard, metal mesh,

wire-reinforced glass, metal sheeting, large

mirrors, suspended ceilings, elevator shafts,

etc. These can all reflect and thereby reduce the

signaling capability of the transmitter.  A little

forethought prior to installation, coupled with a

few tests, will avoid most problems.

BNC Connector

Summary of Contents for 3007 Series

Page 1: ...Microframe Corporation Series 3007 DataPage Lite Transmitter Operating Manual B3007 7012 B3007 7012 ...

Page 2: ...INSTALLATION SPECIFICATIONGUIDE ITEM NO A3007 7012 REVISION DATE 07 02 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Page 3: ...nsformers linecords andelec tricalequipmentshouldbekeptoutofthereach of children and away from water Life Support Policy Microframe s products are not autho rized for use as components in life sup port devices or systems without the ex press written approval of the president of Microframe Corporation As used herein 1 Life support devices or systems are de fined as systems which support or sustain ...

Page 4: ... 2 RANGE EXPANSION 9 3 3 IMPORTANTINFORMATION 9 3 4 SAFETY INFORMATION 9 3 5 CARE OF TRANSMITTER 9 3 6LIABILITY 9 3 7 WARRANTY INVALIDATION 9 3 8 SERVICE INFORMATION 9 5 GEO PULSAR USER GUIDE 10 5 1 TURNING ON THE PAGER 10 5 2 SENDING A PAGE 10 5 3 SENDING AN ALPHA MESSAGE 10 5 4 SENDINGANUMERIC MESSAGE 10 5 5 RECEIVINGAPAGE 10 5 6 SENDING A GROUP CALL PAGE 10 5 7 MANUAL PAGER TURN OFF 10 5 8 PAGE...

Page 5: ... P O Box 1700 Broken Arrow OK 74013 Features The DataPage Lite Transmitter can send a 12 digit numericmessagecodetoanyof9 999differentpagers Sinceyouownthetransmitter s andreceivers youcan enjoy unlimited paging with no monthly service fee Available for desk mount only Operation The DataPage Lite is a simple plug and play system Once the transmitter is plugged in and batteries are inserted into th...

Page 6: ...GER 1 9999 The flashing cursor invites you to enter a pagernumber thiscanbeanynumberbetween 1 and 9 999 after which you must press SEND to transmit a page See Operation for further transmittingprocedures IMPORTANT NOTE Use only the power supply included with your system The use of non approved power supplies will invalidate all war ranty and service We also recommend using a surge suppressor for p...

Page 7: ... call number is 900 unless otherwise specified by the cus tomer 2 3 PAGER TURN OFF FROM BASE Enter the pager number followed by the ENTER key Press ENTER again to bypass Beep Type screen When screen reads Enter Mesage type the code 123456 followed by SEND NOTE The two left parenthesis before the number are required or it will not work 2 4TURNINGOFFALLPAGERS To simultaneously turn all pagers off at...

Page 8: ...INFORMATION Theseproductsaredesignedtooperatesafely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT subject this equipment to Mechanical shock Excessive humidity or moisture Extremes of temperature Corrosiveliquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in class...

Page 9: ... on the pager screen until the pager stops vibrating To view themessageafterthepagerhasstoppedvibrat ing pressthe LARGEBLACKBUTTON once 5 6SENDINGAGROUPCALLPAGE All pagers respond to call number 900 unless another group call number has been chosen To page all pagers at once simply enter 900 and SEND 5 7MANUALPAGERTURN OFF Pressthe RIGHTARROWBUTTON The words PGR OFF will appear on the LCD screen Pr...

Page 10: ...towardstheground Avoid mounting the dipole on or near to any metal girders pilars or other metallic obstructions The dipole should preferably be mounted at a height which avoids potential snagging with any moveable objects that might be used in the vicinity e g ladders Ensure that the bracket is firmly bolted to a solid suface and that the feeder cable is adequately clamped along it s entire run b...

Page 11: ...ration Series 3007 DataPage Lite Transmitter 12 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Reviews: