![Microcyber CS-TT106H-V2.0 User Manual Download Page 26](http://html1.mh-extra.com/html/microcyber/cs-tt106h-v2-0/cs-tt106h-v2-0_user-manual_1786196026.webp)
Temperature Transmitter | NCS TT106 | Page
Email | [email protected]
http://www.microcyber-fieldbus.com
21
accuracy
1.2 RTD Parameter
RTD Parameter at Normal Temperature
Signal
type
Suggested range
Accuracy
(
25
℃)
Temperature drift
(
per
℃)
Resistance
Signal
0~500Ω
±0.04Ω
±0.001Ω
0~4000Ω
±0.35Ω
±0.015Ω
PT100
-200 ~ 850
℃
±0.15
℃
±0.003
℃
PT1000
-200 ~ 850
℃
±0.15
℃
±0.005
℃
CU50
-50 ~ 150
℃
±0.15
℃
±0.005
℃
CU100
-50~ 150
℃
±0.10
℃
±0.003
℃
RTD Other Parameter
Wiring
2
、
3
、
4
Common
Mode
Rejection
≥70dB
(
50Hz and 60Hz
)
Series
Mode
Rejection
≥70dB
(
50Hz and 60Hz
)
1.3 Thermocouple
Thermocouple Parameter at Normal Temperature
Signal type
Suggested range
Accuracy
(
25
℃)
Temperature drift
(
per
℃)
mV
-100mV ~ +100mV
±0.025mV
±0.001 mV
B
500
℃
~ 1810
℃
±0.77
℃
±0.050
℃
E
-200
℃
~ 1000
℃
±0.20
℃