IBEX 8 Nozzle
SMALL FRAME_June 2020
June 20 Page 11 of 41
8.
PRESSURIZING THE SYSTEM
8.1 ABOUT PRESSURE REGULATOR
The regulator is set as a safety valve should the system pressure exceed IBEX: 1,100 PSI (75.8 Bar). At
extremely low flow, the regulator will bypass water back into the pump head as the VFD drive has
reached its minimum Frequency (Hertz).
8.2 PROCEDURE TO RESET THE PRESSURE REGULATOR
ABOUT THE PRESSURE REGULATOR
: ADJUSTMENTS SHOULD NOT BE MADE TO REGULATOR. ONLY
FOLLOW THIS RESET PROCEDURE IF REGULATOR IS REPLACED OR WHEN REPLACING PUMP HEAD.
Safety glasses must be worn when adjusting pressure. Always keep guards and covers in place.
NEVER DISASSEMBLE THE REGULATOR UNDER PRESSURE!!!
If for any reason the regulator is adjusted, or changed, follow this procedure to reset the correct adjustment.
1.
Press F3 (IBEX) to turn off the pump.
2.
Turn off the electrical supply at the disconnect switch to electrically isolate the pump.
3.
Locate the pressure transducer and unplug the electrical lead by squeezing the clip.
4.
Restore the power and start the unit by pressing F1.
5.
Adjust the regulator by turning
*
clockwise or counter-clockwise until the pressure gauge indicates 1,100 psi
(75.8 Bar) for IBEX. When the pressure is steady at 1,100 make sure that the “Jam Nut” is tightened to lock
the adjustment in position. [*
Clockwise:
increase pressure.
Counterclockwise:
decrease pressure.]
6.
Press F3(IBEX) or F2(FOCUS) to stop pump, shut off power. Plug electrical lead back into transducer,
restore electrical power.
7.
See Manual for ‘PRESSURIZING SYSTEM’. Once the maximum pressures are achieved (above), system will
fall back and maintain pressure
IBEX: 1,000 PSI.
Example:
Pressure
regulator assembly.
Example:
Pressure regulator
assembled on pump head.
Example:
Pressure regulator
assembled on pump head.
IBEX: Where to locate pressure
transducer underneath pump.
Locate transducer
underneath pump.
Summary of Contents for IBEX 1000
Page 31: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 31 of 41 IBEX 1 3 GALLON REAR VIEW...
Page 32: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 32 of 41 IBEX 1 3 GALLON RIGHT SIDE VIEW...
Page 33: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 33 of 41 IBEX 1 3 GALLON LEFT SIDE VIEW...
Page 34: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 34 of 41 IBEX 1 3 GALLON TOP VIEW...
Page 35: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 35 of 41 IBEX 1 3 GALLON INTERNAL TOP VIEW...
Page 36: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 36 of 41 IBEX 1 3 GALLON BOTTOM VIEW...
Page 37: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 37 of 41 IBEX 1 3 GALLON 240V CONTROL PANEL...
Page 38: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 38 of 41 IBEX 1 3 GALLON 480V CONTROL PANEL...
Page 39: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 39 of 41 IBEX 1 3 GALLON NOTES 1...
Page 40: ...IBEX 8 Nozzle SMALL FRAME_June 2020 June 20 Page 40 of 41 IBEX 1 3 GALLON NOTES 2...