Operation
2012-2014 Microchip Technology Inc.
DS50002081B-page 17
2.4
TARGET COMMUNICATION CONNECTIONS
2.4.1
Standard Communication Target Connection
Using the RJ-11 connector, the MPLAB ICD 3 In-Circuit Debugger is connected to the
target device with the modular interface (six conductor) cable. The pin numbering for
the connector is shown from the bottom of the target PCB in
.
FIGURE 2-3:
STANDARD CONNECTION AT TARGET
2.4.2
Target Connection Circuitry
shows the interconnections of the MPLAB ICD 3 In-Circuit Debugger to the
connector on the target board. The diagram also shows the wiring from the connector
to a device on the target PCB. A pull-up resistor (usually around 50 k
) connected from
the V
PP
/MCLR line to the V
DD
is recommended so that the line may be strobed low to
reset the device.
FIGURE 2-4:
STANDARD CONNECTION TARGET CIRCUITRY
Note:
Cable connections at the debugger and target are mirror images of each
other, i.e., pin 1 on one end of the cable is connected to pin 6 on the other
end of the cable. See
Section B.5.2.3 “Modular Cable Specification”