INTRODUCTION
1.
INTRODUCTION
The Microcare Web-Logger can be used as a standalone Microcare device monitor and/or can be
connected to operate in conjunction with a Microcare Battery Monitor.
In order to connect a Web-Logger to your Microcare devices, the following items are required:
1. Microcare Web-Logger.
2. Internet enabled router with at least one open port.
3. DHCP enabled on the router.
4. Microcare Battery Monitor or at least one Microcare device with a MC-Coms converter.
Connecting up:
1.1
Standalone (no Microcare Battery Monitor) wiring diagram:
In this configuration, a single Microcare MPPT is connected to a MC COMS converter. The MC
COMS converter is then connected to the MC COMS port of the Web-Logger. The LAN or Ethernet
port of the Web-Logger is then connected to an Internet enabled router.
The Web-
Loggers’ power is supplied by the connected battery bank. Supply voltage to not exceed
70V DC!
Internet Connection - LAN
MC COMMS Ports
WEB LOGGER