background image

 

 

9

 

9. 

REGISTRATION OF MY MICROCARE PRODUCT 

 

Product  Serial Number: 

 

 

 
Product Description: 

 

 

 
Date Purchased 

 

 

 

From Whom was the Inverter Purchased

:  

 
Company Name  
 
Contact Person  
 
Contact Number  
 
E-mail Address  
 

 

Installation Company Information

:  

 
Company Name  
 
Contact Person  
 
Contact Number  
 
E-mail Address  
 

 

 

Details of Product Owner

 

 
Name & Surname 
 
Address 
 
City & Province 
 
Contact Number  

 

 

 

 
E-mail Address  
 
Date Installed 
 
Microcare: 

1

st

 Floor, Neave Industrial Park, Korsten, Port Elizabeth 

 

 

P.O.Box 7227, Newton Park, 6055 

 

 

 

Tel: 041 453 5761, Fax: 041 

– 453 5763 

 

 

Technical Support  e-mail: [email protected] 

 

 

Website: www.microcare.co.za 

 
Registration by  fax:  

041 

– 453 5763 

Registration by e-mail:  

[email protected] 

Online Registration:  

www.microcare.co.za/register-my-product 

Summary of Contents for 600W-24V

Page 1: ...Pure Sine Wave Inverter 600W 24V User Manual Manual Version INV 600W 2016 1...

Page 2: ...s 5 5 2 1 Inverter Switched Off 5 5 2 2 Inverter Switched ON 5 5 2 3 Overload 5 5 2 4 Battery Low High 6 5 2 5 Temp 6 5 3 Connecting the Load 6 6 MAINTENANCE AND SERVICE 6 6 1 Fuse Replacement 6 7 SP...

Page 3: ...he Inverter as close as possible to the batteries in order to keep the battery cables as short as possible as supplied with the inverter 2 2 Precautions When Working With Batteries Ensure that the inv...

Page 4: ...verter Front View Figure 3 1 3 2 Inverter Bottom View Figure 3 2 1 230V AC Outlet 2 Cooling Fan 3 2 x 30A Fuses 4 Battery Cable Positive 5 Battery Cable Negative 6 Ventilation Holes 1 2 4 3 6 5 LED In...

Page 5: ...ED starts flashing 4 2 Battery Connection Methods 4 2 1 Series Battery Connection Current remains at 100AH 12V 12v 24V Series Connection Amperage stays the same as a single battery voltage increases 4...

Page 6: ...tches the inverter ON or OFF resets the inverter 5 2 Inverter Status LED s 5 2 1 Inverter Switched Off 5 2 2 Inverter Switched ON 5 2 3 Overload STATUS LED Blinking indicates that the inverter is swit...

Page 7: ...caused by DC reverse polarity short circuit or overload To check the fuses Disconnect all AC loads Disconnect the Battery Remove the Fuses as indicated in on diagram 3 2 Visually inspect each of the 2...

Page 8: ...Voltage 230VAC Output Frequency 50Hz Surge Rating 200 Efficiency 95 Output Waveform Sine Wave THD 93 Protection Fuse Short Circuit Reverse Polarity Over Temperature Recommended Battery Size 2x 12V Min...

Page 9: ...are our sole remedies Destrier Electronics shall not be liable for damages whether direct incidental special or consequential even caused by negligence or fault Destrier Electronics owns all parts re...

Page 10: ...r E mail Address Details of Product Owner Name Surname Address City Province Contact Number E mail Address Date Installed Microcare 1st Floor Neave Industrial Park Korsten Port Elizabeth P O Box 7227...