12
To change the menu, push the UP button, The menu will then change to:
The settings available are as follows:
AC OUTPUT = NOR
-
This will allow the inverter to supply rated power.
A 5Kw Inverter will supply 5kw of Power.
AC OUTPUT = 200%
-
This will allow the inverter to supply 200% rated power.
A 5Kw Inverter will supply 10kw of Power.
If the grid fails and the load is exceeding 100% of
the inverter power, the inverter will shut down due
to overload.
To change the menu, push the UP button, The menu will then change to:
The settings available are as follows:
NO DELAY
As soon as Grid power is available the Inverter will synchronise and
switch from battery to Grid.
DELAY = 30Sec
30 seconds after Grid power is available the Inverter will
synchronise and switch from battery to Grid.
DELAY = 5 Min
5 minutes after Grid power is available the Inverter will synchronise
and switch from battery to Grid.
It would be a good idea to select a 30 seconds or 5 minute delay after load shedding to allow the
grid power to stabilise.
IF AC INPUT
=
ON
AC OUTPUT
=
NOR
MICROCARE
ON
OFF
ENTER
Menu Down
Menu Up
OK
Inverter
Error
LOAD
TRANSFER
NO DELAY
MICROCARE
ON
OFF
ENTER
Menu Down
Menu Up
OK
Inverter
Error
Summary of Contents for 1kW24V