Maintenance

Wick and Scent Pad Replacement

3

Figure 9.

Scent Pad

UVC Cover

Scent pad replacement:

Your humidifier is equipped with a compartment that can hold scented medicine 

pads. These typically are scented with mentholatum to help with congestion.  The  

pads will last approximately 24 hours before needing to be replaced. Use of these 

medicine pads is optional and not necessary to operate the unit.

1.  Turn the humidifier off.

2.  The scent pad compartment is located on the back of the humidifier directly 

under the UVC cover.

3.  Slide  your  finger  underneath  the  edge  of  the  scent  pad  compartment  and 

gently pull outward. Figure 9. The scent pad is located inside the compartment. 

4.  Remove the used scent pad and replace with a new one. Slide the scent pad 

compartment back into the unit until it snaps into place.

5.  Turn the unit back on and resume operation.

Wick replacement:

The wick in your humidifer is made to last for an entire running season, about 4 

months. It is possible, depending on the quality of water in your area, that it may 

have to be changed more frequently.

1.  Turn the humidifier off and unplug it from the wall outlet.

2.  Remove the tank for the housing.

3.  Locate the 3 lock tabs in the base of the unit. Turn them clockwise until the 

base of the tab lines up with the indentions in the base and lift off the housing. 

Figure 10.

4.  Locate and turn the lock tab clockwise on the base holding the wick frame. 

Remove the wick frame and set it aside. Figure 11.

5.  Remove the old wick by pulling the bottom of the wick out of the frame first 

and discard.

6.  Insert the new wick top first. Ensure the wick is in between the tabs at the top 

of the wick frame then slide the bottom part of the wick into the frame, making 

sure not to crush the bottom corners of the wick.

7.  Reassemble the unit and refill the water tank if necessary.

8.  Turn the unit back on and resume operation.

Figure 10.

Lock Tabs

Figure 11.

Figure 12.

Summary of Contents for 36518

Page 1: ...1 2011 Microban EvaporativeTower EvaporativeTower EvaporativeTower Form 44073 01 20110518 2011 Microban Humidifier Owner s Guide Model 36518 English...

Page 2: ...tial Setup and Operation 5 Controls 6 Maintenance Cleaning and Storage 7 Wick and Scent Pad Replacement 8 UVC Replacement 9 Humidifier Assistance Troubleshooting 10 Support and Service Parts 11 Warran...

Page 3: ...idifier while it is in operation Empty the water tank turn off and unplug the unit before moving In addition to routine maintenance which may be required this humidifier requires seasonal cleaning Ref...

Page 4: ...4 44073 01 05 18 2011 At A Glance Know Your Humidifier 1 Tank Tank Cap UV Bulb UV Cover Scent Pad Compartment Wick Wick Frame Water Tray Base Housing Tank Handle Housing Handle...

Page 5: ...he unit until the clip at the top releases then pull the tank upward and out Figure 1 5 Turn the tank upside down and remove the tank cap by turning counter clockwise Figure 2 6 Fill the tank with cle...

Page 6: ...unit to output The humidty knob is a percentage ranging from 30 at it s lowest to 80 at the highest Turn the knob clockwise to increase humidity output When the humidifier has reached the set humidity...

Page 7: ...lift off the housing Figure 6 and Figure 7 6 Locate and turn the lock tab clockwise on the base holding the wick frame Remove the wick frame and set it aside Figure 8 7 Fill the Water Tank with a mix...

Page 8: ...operation Wick replacement The wick in your humidifer is made to last for an entire running season about 4 months It is possible depending on the quality of water in your area that it may have to be c...

Page 9: ...the indentions on either side of the UVC Cover and pull straight out Figure 13 6 Remove the UVC bulb from the UVC cover by turning counterclockwise NOTE When handling the new bulb do not let it come...

Page 10: ...humidity knob Once the room reaches the set humidity level the humidifier will turn OFF this is normal Problem Mineral build up on the Water Tank or Tray Solution 1 Refer to the section Cleaning and...

Page 11: ...d 8 00 am to 5 00 pm on Saturday Central Time You may also contact us over the Internet at www hunterfan com or register your product at www hunterfan com register and select your product under produc...

Page 12: ...not cover Humidifiers used in commercial applications There are no express or implied warranties as to commercial purchasers or users To obtain service contact the nearest Hunter authorized service c...

Reviews: