background image

3

©2011 Microban

At A Glance

Warnings and Introduction

1

Important Safety Instructions: Read all instructions before using this humidifier.

WARNING: 

This humidifier emits UV radiation that may cause eye and/or skin irritation. RG-3. Avoid exposing eyes and skin to 

unshielded UVC Lamp. 

Caution:

 The UVC Lamp may shatter and cause injury if it is dropped or sustains impact. Wear safety glasses and gloves when handling 

the UVC Lamp. Do not use excessive force when handling the UVC Lamp. Dispose of the UVC bulb in accordance with local or State 

guidelines as trace amounts of Mercury are present.

•  This humidifier may not work properly on an uneven surface. 

ALWAYS

 place this humidifier on a firm, level, and water 

resistant surface. ALWAYS place the humidifier at least six (6) inches away from walls and heat sources such as stoves, 

radiators, or heaters.

•  ALWAYS place the humidifier in an area that is out of the reach of children.

•  Before using the humidifier, extend the cord and inspect for any signs of damage. 

DO NOT

 use the product if the cord 

has been damaged.

•  This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized 

outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified 

electrician. 

DO NOT

 attempt to defeat or override this safety feature.

•  ALWAYS UNPLUG AND EMPTY the humidifier when it is not in operation or while it is being cleaned.

•  Never move the humidifier while there is water in the tank. 

DO NOT

 tilt or move the humidifier while it is in operation. 

Empty the water tank, turn off, and unplug the unit before moving.

•  In addition to routine maintenance which may be required, this humidifier requires seasonal cleaning. Refer to and follow 

“Cleaning and Storage” on page 7.

•  Thank you for purchasing The Evaporative Humidifier by Microban

®

. Please read and save these instructions to receive 

the maximum benefit and performance from your humidifier.

•  Never fill the humidifier tank with hot water. Always use clean, cool tap water.

ReAD AND SAve THeSe INSTRUCTIONS

The  Microban

®

  evaporative  Humidifier  has  a  unique  patented  design  with  several  innovative 

features:

•   Low Maintenance – Our paper wicks are designed to last one full humidifer season.  

•   Regulated Release™ System – By dispersing water from the top of the wick, stagnant water around the wick is elimnated, 

and the buildup of mineral residue that can clog the wick and impede performance is eliminated.

•   Built-in Antimicrobial Properties – We use Microban

®

 on many of the plastic parts and wick. This helps inhibit the growth 

of bacteria, mold and fungi that may affect these parts.

NOTe: 

This product contains antimicrobial properties which are built-in to inhibit the growth of bacteria which may affect 

the plastic and wick in the humidifier. These properties do not extend to the water, humidified air, or users. Conduct routine 

cleaning and maintenance based upon use and individual conditions.

•   No White Dust – The Microban

®

 Evaporative Humidifier produces no white dust that can settle on furniture or be inhaled.

•  UVC Lamp - This Microban

®

 Humidifier is equipped with a UVC germicidal lamp. UVC technology is a proven germicide 

that is accepted by the FDA and EPA as having the ability to kill pathogens in air and water that is exposed to UVC light.

Summary of Contents for 36518

Page 1: ...1 2011 Microban EvaporativeTower EvaporativeTower EvaporativeTower Form 44073 01 20110518 2011 Microban Humidifier Owner s Guide Model 36518 English...

Page 2: ...tial Setup and Operation 5 Controls 6 Maintenance Cleaning and Storage 7 Wick and Scent Pad Replacement 8 UVC Replacement 9 Humidifier Assistance Troubleshooting 10 Support and Service Parts 11 Warran...

Page 3: ...idifier while it is in operation Empty the water tank turn off and unplug the unit before moving In addition to routine maintenance which may be required this humidifier requires seasonal cleaning Ref...

Page 4: ...4 44073 01 05 18 2011 At A Glance Know Your Humidifier 1 Tank Tank Cap UV Bulb UV Cover Scent Pad Compartment Wick Wick Frame Water Tray Base Housing Tank Handle Housing Handle...

Page 5: ...he unit until the clip at the top releases then pull the tank upward and out Figure 1 5 Turn the tank upside down and remove the tank cap by turning counter clockwise Figure 2 6 Fill the tank with cle...

Page 6: ...unit to output The humidty knob is a percentage ranging from 30 at it s lowest to 80 at the highest Turn the knob clockwise to increase humidity output When the humidifier has reached the set humidity...

Page 7: ...lift off the housing Figure 6 and Figure 7 6 Locate and turn the lock tab clockwise on the base holding the wick frame Remove the wick frame and set it aside Figure 8 7 Fill the Water Tank with a mix...

Page 8: ...operation Wick replacement The wick in your humidifer is made to last for an entire running season about 4 months It is possible depending on the quality of water in your area that it may have to be c...

Page 9: ...the indentions on either side of the UVC Cover and pull straight out Figure 13 6 Remove the UVC bulb from the UVC cover by turning counterclockwise NOTE When handling the new bulb do not let it come...

Page 10: ...humidity knob Once the room reaches the set humidity level the humidifier will turn OFF this is normal Problem Mineral build up on the Water Tank or Tray Solution 1 Refer to the section Cleaning and...

Page 11: ...d 8 00 am to 5 00 pm on Saturday Central Time You may also contact us over the Internet at www hunterfan com or register your product at www hunterfan com register and select your product under produc...

Page 12: ...not cover Humidifiers used in commercial applications There are no express or implied warranties as to commercial purchasers or users To obtain service contact the nearest Hunter authorized service c...

Reviews: