Maintenance

Cleaning and Storage

3

Many regions have hard water with high concentrations of minerals. When water 

evaporates  from  The  Microban

®

  Evaporative  Humidifier,  minerals  may  be  left 

behind. These minerals can form a hard white scale which can be removed by 

following these cleaning instructions. The frequency of cleaning due to mineral 

build up can vary depending upon the quality of water you may have. Refer to 

“Know Your Humidifier” on page 4 for part names.

To clean the humidifier:

1.  Turn the unit off and unplug it from the wall outlet.

2.  Remove the tank by pulling the tank handle away from the unit until the clip 

at the top releases, then pull the tank upward and out. Figure 5.

3.  Turn  the  tank  upside  down  and  remove  the  tank  cap  by  turning  counter-

clockwise.

4.  Drain any remaining water from the tank and shake gently to remove trapped 

water and the demineralization cartridge. Set the demineralization cartridge 

aside for now.

5.  Locate the 3 lock tabs in the base of the unit. turn them clockwise until the 

base of the tab lines up with the indentions in the base and lift off the housing. 

Figure 6. and Figure 7.

6.  Locate and turn the lock tab clockwise on the base holding the wick frame. 

Remove the wick frame and set it aside. Figure 8.

7.  Fill the Water Tank with a mixture of one (1) gallon of water and eight (8) 

ounces of white vinegar. Leave the mixture in the Water Tank for 20 minutes, 

giving the Water Tank a shake every few minutes. After 20 minutes, give the 

Water Tank a final shake and discard the mixture.

8.  Rinse the Water Tank several times with clean water. Leave the Water Tank 

Cap off to allow the Water Tank to dry completely. 

9.  Fill the Tray with a mixture of one (1) gallon of water and eight (8) ounces of 

white vinegar. Leave the mixture in the Tray for 20 minutes, then discard the 

mixture. Rinse the Tray well with clean water and let it air dry or wipe it dry 

with a cloth.   

10.  Wipe the surfaces of the main housing with a soft damp cloth.

11.  Once all the parts are clean and dry, reassemble the humidifier, refill the 

water tank and resume use.

Storing the humidifier:

When storing the unit, follow the cleaning instructions above. Ensure that all parts 

of the humidifier are dry and discard the used wick before reassembling the unit. 

Store in a cool dry place until you the humidifier is needed next season.

Figure 5.

Figure 6.

Lock Tabs

Figure 7.

Figure 8.

Summary of Contents for 36518

Page 1: ...1 2011 Microban EvaporativeTower EvaporativeTower EvaporativeTower Form 44073 01 20110518 2011 Microban Humidifier Owner s Guide Model 36518 English...

Page 2: ...tial Setup and Operation 5 Controls 6 Maintenance Cleaning and Storage 7 Wick and Scent Pad Replacement 8 UVC Replacement 9 Humidifier Assistance Troubleshooting 10 Support and Service Parts 11 Warran...

Page 3: ...idifier while it is in operation Empty the water tank turn off and unplug the unit before moving In addition to routine maintenance which may be required this humidifier requires seasonal cleaning Ref...

Page 4: ...4 44073 01 05 18 2011 At A Glance Know Your Humidifier 1 Tank Tank Cap UV Bulb UV Cover Scent Pad Compartment Wick Wick Frame Water Tray Base Housing Tank Handle Housing Handle...

Page 5: ...he unit until the clip at the top releases then pull the tank upward and out Figure 1 5 Turn the tank upside down and remove the tank cap by turning counter clockwise Figure 2 6 Fill the tank with cle...

Page 6: ...unit to output The humidty knob is a percentage ranging from 30 at it s lowest to 80 at the highest Turn the knob clockwise to increase humidity output When the humidifier has reached the set humidity...

Page 7: ...lift off the housing Figure 6 and Figure 7 6 Locate and turn the lock tab clockwise on the base holding the wick frame Remove the wick frame and set it aside Figure 8 7 Fill the Water Tank with a mix...

Page 8: ...operation Wick replacement The wick in your humidifer is made to last for an entire running season about 4 months It is possible depending on the quality of water in your area that it may have to be c...

Page 9: ...the indentions on either side of the UVC Cover and pull straight out Figure 13 6 Remove the UVC bulb from the UVC cover by turning counterclockwise NOTE When handling the new bulb do not let it come...

Page 10: ...humidity knob Once the room reaches the set humidity level the humidifier will turn OFF this is normal Problem Mineral build up on the Water Tank or Tray Solution 1 Refer to the section Cleaning and...

Page 11: ...d 8 00 am to 5 00 pm on Saturday Central Time You may also contact us over the Internet at www hunterfan com or register your product at www hunterfan com register and select your product under produc...

Page 12: ...not cover Humidifiers used in commercial applications There are no express or implied warranties as to commercial purchasers or users To obtain service contact the nearest Hunter authorized service c...