Special Calibration Settings - Page 4
MF. FLOW TRIGGER THRESHOLD
MULTIFUNCTION OUTPUT
FLUSH DELAY TIME
FLUSH TIME
FLUSH DELAY TIME
Location:
PAGE 4 - PRESSURE
Description:
When Multifunction output is set to FLUSH,
this enables and adjusts a time delay from the RUN/HOLD
transition to the start of the Flush cycle. This can be set to OFF
(0) or from 1-6 seconds.
Default:
0
FLUSH TIME
Location:
PAGE 4 - SPEED
Description:
When Multifunction output is set to FLUSH, this
enables and adjusts the duration of the Flush cycle. This can
be set to OFF (0) or from 1-12 seconds.
Default:
0
MULTIFUNCTION FLOW TRIG. THRESHOLD
Location:
PAGE 4 - AREA
Description:
When Multifunction output is set to Fixed Flow
Trigger (F-FLO) or Proportional Flow Trigger (P-FLO), this
adjusts the threshold value in Volume/Minute for activating
the voltage output. The output will turn off if Volume/
Minute is reduced to 95% of the threshold value. This fixed
margin is maintained to reduce on/off cycling if system is
operating at or near threshold setting.
F-FLO:
Threshold value turns on power to Multifunction
output based on the fixed total flow rate, regardless of
active width.
P-FLO:
Threshold value turns on power to Multifunction
output based on flow rate, proportional to active width.
Example: If the threshold is set to 10gpm while running only
2 out of 5 sections, the trigger would start output at 4gpm -
(2/5 X 10).
Default:
15.0 gpm
MULTIFUNCTION OUTPUT
Location:
PAGE 4 - DISTANCE
Description:
Selects mode of 12VDC power sent to
Multifunction Output connection on branch harness.
Default setting this function is Master.
1.
OFF
= Always off
2.
ON
= Always on
3.
RELIEF VALVE
= On in Hold
4.
MASTER
= On in Run and at least 1 section on
(Note: there is a 1/2 second delay switching from HOLD to RUN)
5.
FLUSH
= Enables Flush cycle to purge chemicals from
lines when switching from Run to Hold - see below
6.
F-FLO
= Fixed Flow Trigger - see above
7.
P-FLO
= Proportional Flow Trigger- see above
8.
ON IN RUN ONLY
= On in Run - NOT affected by sections.
Default:
Master (off in Hold)
1 2 3 4
1
2
3
4
MINIMUM ALARM SPEED
AUDIBLE ALARM ENABLE
SECTION INPUT POLARITY
—
MINIMUM ALARM SPEED
Location:
PAGE 4 - VOLUME
Description:
Enables and adjusts a minimum speed
threshold for the audible alarm - this prevents unneeded
warnings while stopping and starting. This can be set
to OFF (0) or from 0.1 to 99.9 mph (km/h). Affected
alarms are Application Rate Error and Minimum Flow.
Default:
Off
AUDIBLE ALARM ENABLE
Location:
PAGE 4 - VOLUME/MIN.
Description:
Enables (ON) or disables (OFF) Audible Alarm
function - allows user to operate system without hearing
any system warnings. Flush cycle completion alert is not
affected by this setting.
Default:
On
SECTION INPUT POLARITY
Location:
PAGE 4 - TANK
Description:
This setting allows the user to reverse
the polarity of section inputs. This may be useful
when connecting a 3rd party mapping device to the
SprayMate XRS system for automatic section control.
Default:
12v
Setting Locations
Page
Page